background image

 

8

PROTHO Technical Manual  

 

 

 

 

 

 

          

               Bores Group S.r.l.

 
The device can only be energised for starting once 
the operations are concluded and once you have 
moved away from the device 

9 WARRANTY TERMS 

 

This peristaltic metering pump (defined in the 
following points more simply as pump or 
device) is guaranteed for  a period of one year 
from the date of purchase which is proved by a 
document valid for fiscal purposes issued by 
the Retailer or the Manufacturer, which shows 
the date in which the purchase was made. 

 

The fiscal document that proves the date of 
purchase, issued by the Retailer or the 
Manufacturer, must be kept together with this 
instruction manual; both must be exhibited to the 
technical personnel in the case of work done in the 
warranty period. 

 Warranty is understood to be the free replacement 

or repair of the parts that prove to be defective in 
origin or because of manufacturing flaws. 

 The user is obliged to pay the “fixed call-out fee” 

should she/he require the work to be done at 
her/his own home. 

 All the parts that prove to be defective due to the 

carelessness of negligence in use (failure to comply 
with the instructions for the operation of the device), 
or incorrect installation and maintenance carried out  

 

 

by personnel that are not professionally qualified, 
transport damages, that is due to circumstances 
that in any case cannot be traced back to 
manufacturing defects in the device are not covered 
by the warranty. 

 Work inherent to the installation and the connection 

of supply systems as well as the maintenance 
mentioned in this instruction manual are also 
excluded from the warranty services. 

 The warranty is also excluded in all cases of 

improper use of the pump. 

 

The Manufacturer declines all responsibility for 
any damages that might, directly or indirectly, 
be caused to people, objects and animals as a 
result of the failure to comply with the 
directions indicated in this instruction manual 
and especially those which concern the 
directions about the installation, use and 
maintenance of the device. 

 If the device is repaired at an Authorised Service 

Centre or by the Manufacturer, the transport risks 
are at the expense of the User. 
In any case, the transport costs are understood to 
be at the expense of the User. 

 In any circumstance the extension of the warranty 

in the event that a fault should occur is excluded.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for PROTHO

Page 1: ...INSTRUCTION MANUAL Peristaltic Pump for cleansing agents PROTHO...

Page 2: ...2 PROTHO Technical Manual Bores Group S r l Rev 01 del 151008...

Page 3: ...NING PRINCIPLE page 4 2 3 RATING page 4 3 INSTALLATION page 4 3 1 POSITIONING page 4 3 2 CONNECTING TO THE MAINS SUPPLY page 5 3 3 WATER CONNECTIONS page 5 4 STARTING page 6 4 1 REGULATING THE CAPACIT...

Page 4: ...away into the environment Arrange for the disposal and the recovery of the materials in accordance with the relevant national laws in force For this reason we urge you to give maintenance work and re...

Page 5: ...not to damage the various components Now connect the wires that come out of the pump container one to earth to the casing of the machine the other to the fastener on the detergent sensor previously i...

Page 6: ...l and water connections of the metering pump are complete you can proceed to starting it When starting the pump for the first time the dishwashing machine has to perform several washing cycles on empt...

Page 7: ...ipe from breaking through wear Maintenance on this component must be carried out by competent and professionally qualified personnel from a Service Centre and demanding the use of original spare parts...

Page 8: ...ss of negligence in use failure to comply with the instructions for the operation of the device or incorrect installation and maintenance carried out by personnel that are not professionally qualified...

Page 9: ...1 0 4 3 2x6 4 3 PDE3 3 0 92 3 3 6 4x1 6 0 1 PDE4 0 1 12 4 0 6 4x1 6 0 1 PDER3 3 0 92 3 3 6 4x1 6 0 1 PBE1 0 0 28 1 0 3 2x6 4 3 PDE8 0 2 24 8 0 6 4x1 6 0 1 PDE8 024 2 24 8 0 6 4x1 6 0 1 PDER8 024 2 24...

Page 10: ...10 PROTHO Technical Manual Bores Group S r l 11 EXPLODED VIEW OF THE METERING PUMP WITHOUT CONTAINER...

Page 11: ...11 PROTHO Technical Manual Bores Group S r l 12 EXPLODED VIEW OF THE METERING PUMP WITH CONTAINER...

Page 12: ...n elbow for detergent injection complete SENSC Sensor for detergent conductimetric control card FILFIC VALFC Stainless steel bottom filter complete Stainless steel bottomfilter with non return valve c...

Page 13: ...plete with pipe fitting TUBS3264ABC Silicone pipe for rinse aid complete with pipe fittine with non returne valve ROCPPC ROCPPBC Support with Protho rollers for detergent complete Support with Protho...