background image

 

11

PROTHO Technical Manual  

 

 

 

 

 

 

                   Bores Group S.r.l. 

 

12 EXPLODED VIEW OF THE METERING PUMP WITH CONTAINER 

Summary of Contents for PROTHO

Page 1: ...INSTRUCTION MANUAL Peristaltic Pump for cleansing agents PROTHO...

Page 2: ...2 PROTHO Technical Manual Bores Group S r l Rev 01 del 151008...

Page 3: ...NING PRINCIPLE page 4 2 3 RATING page 4 3 INSTALLATION page 4 3 1 POSITIONING page 4 3 2 CONNECTING TO THE MAINS SUPPLY page 5 3 3 WATER CONNECTIONS page 5 4 STARTING page 6 4 1 REGULATING THE CAPACIT...

Page 4: ...away into the environment Arrange for the disposal and the recovery of the materials in accordance with the relevant national laws in force For this reason we urge you to give maintenance work and re...

Page 5: ...not to damage the various components Now connect the wires that come out of the pump container one to earth to the casing of the machine the other to the fastener on the detergent sensor previously i...

Page 6: ...l and water connections of the metering pump are complete you can proceed to starting it When starting the pump for the first time the dishwashing machine has to perform several washing cycles on empt...

Page 7: ...ipe from breaking through wear Maintenance on this component must be carried out by competent and professionally qualified personnel from a Service Centre and demanding the use of original spare parts...

Page 8: ...ss of negligence in use failure to comply with the instructions for the operation of the device or incorrect installation and maintenance carried out by personnel that are not professionally qualified...

Page 9: ...1 0 4 3 2x6 4 3 PDE3 3 0 92 3 3 6 4x1 6 0 1 PDE4 0 1 12 4 0 6 4x1 6 0 1 PDER3 3 0 92 3 3 6 4x1 6 0 1 PBE1 0 0 28 1 0 3 2x6 4 3 PDE8 0 2 24 8 0 6 4x1 6 0 1 PDE8 024 2 24 8 0 6 4x1 6 0 1 PDER8 024 2 24...

Page 10: ...10 PROTHO Technical Manual Bores Group S r l 11 EXPLODED VIEW OF THE METERING PUMP WITHOUT CONTAINER...

Page 11: ...11 PROTHO Technical Manual Bores Group S r l 12 EXPLODED VIEW OF THE METERING PUMP WITH CONTAINER...

Page 12: ...n elbow for detergent injection complete SENSC Sensor for detergent conductimetric control card FILFIC VALFC Stainless steel bottom filter complete Stainless steel bottomfilter with non return valve c...

Page 13: ...plete with pipe fitting TUBS3264ABC Silicone pipe for rinse aid complete with pipe fittine with non returne valve ROCPPC ROCPPBC Support with Protho rollers for detergent complete Support with Protho...

Reviews: