24
2005 Boreal Geothermal Inc.
www.boreal-geothermal.com
Capacity Data
Model ACDX-65-HAC (nominal 5 ton)
Heating
Ground
Heat of
EAT
LAT
Diff
Btu's
Comp
Comp
Blower
Blower
Total
COP
Suct
Disc
70
62860
70
114.7
44.9
84730
31.8
6551
4.2
414
6965
3.56
80.4
274.0
65
60207
70
113.5
43.5
82080
30.5
6299
4.3
420
6719
3.58
74.7
266.0
60
56347
70
110.6
40.8
76542
29.2
5990
4.3
415
6405
3.50
68.2
255.1
55
50459
71
108.5
38.0
70659
27.8
5721
4.2
413
6134
3.37
62.8
245.9
50
46511
70
105.7
35.7
67164
26.7
5428
4.1
414
5842
3.37
57.2
234.1
45
42117
70
103.0
33.2
62200
25.4
5173
4.1
415
5588
3.26
52.4
224.9
40
38521
70
100.6
31.0
58167
24.1
4904
4.2
410
5314
3.21
47.5
215.0
34
33010
69.8
98.3
28.5
53759
23.0
4611
4.1
412
5023
3.14
41.9
207.2
30
30341
70
96.7
26.7
49725
22.2
4491
4.2
412
4903
2.97
38.8
203.5
Ground
EAT
LAT
Diff
Sens.
Latent
Total
Comp.
Comp
Blower
Blower
Total
EER
Suct
Disc
50
79.9
56.7
23.15
42405
22950
65355
25.9
4342
4.5
415
4757
13.7
66.7
185.7
60
79.9
58.1
21.79
39878
23849
63727
27.4
4415
4.4
420
4835
13.2
70.0
211.6
70
79.5
58.2
21.20
38940
19443
58383
28.4
4515
4.3
415
4930
11.8
69.8
234.8
77
80.1
58.9
21.12
38682
17626
56308
29.6
4630
4.3
415
5045
11.2
71.6
255.5
Cooling
Comp: AH5561E
BM: HE / .5 FHP
G-12 Blower
4 row / 12-circuit air coil
Voltage: 230/1/60
Entering Air: 70DB / 60WB
CFM: 2000
External Static: .2” WC
In accordance with CAN/CSA C748-M94 performance standard for ACDX geothermal heat pumps.
Air Flow
Vs.
External Static Pressure
External Static Pres.
CFM available
.10
1769
.15
1695
.20
1600
.25
1491
.30
1423
G-10 Delhi Blower
External Static Pres.
CFM available
.10
2182
.15
2092
.20
1972
.25
1839
.30
1755
G-12 Delhi Blower