Installation
www.bora.com
2
1
Fig. 5.5
Plinth area air supply
[1]
Optional cable protection (shortened)
[2]
Air supply via the plinth area (opening cross-section ≥ 150 cm²)
i
To ensure a sufficient air supply, an opening cross-
section of at least 50 cm² is recommended in the front of
the kitchen unit, or an opening cross-section of at least
150 cm² in the plinth area.
i
To ensure that the cooktop performs optimally at all
times, there must be sufficient ventilation beneath the
cooktop.
i
The performance of the cooktop is affected or the
cooktop overheats if the warm air beneath the cooktop
cannot escape.
i
If the cooktop overheats, the power is reduced or the
cooktop is switched off completely (see overheating
protection).
i
If cable protection (false floor) is planned beneath the
appliance, this must be fitted so it does not obstruct
ventilation.
X
X
Make sure that the area below the cooktop has a sufficient air
supply.
5.4.4 Special installation instructions for gas
cooktop PKG3
i
Taking into account the applicable valid regulations,
the cooktop must be connected to the gas line with an
upstream stopcock.
i
The gas supply pipe can be connected after the gas
cooktop has been installed.
i
The hose connection must be laid in such a way that it is
not subject to deformation, buckling or abrasion.
i
The stopcock and gas supply pipe connections must be
accessible.
i
It must be possible to inspect the entire length of the
hose line once installed.
i
Only compatible connection pieces are to be used for the
hose line.
i
The pressure regulator must correspond to the set gas
type and set gas pressure and must meet local and legal
requirements.
i
The gas connection hose line must not come into contact
with smoke or the flue outlet of an oven.
i
The hose must not come into contact with hot surfaces
on the cooktop or other appliances.
i
The gas hose must be inspected every 5 years and
replaced if necessary. The gas hose must meet the
requirements of EN14800.
i
If the gas cooktop is used in a model with two cooktop
extractors, it is to be installed at the side. If installed
between the cooktop extractors, the pull of air on both
sides may affect the flames.
Air supply for gas cooktop PKG3
1
2
Fig. 5.4
Air supply at front of the unit
[1]
Air supply via the front of the unit (opening cross-section
≥ 50 cm²)
[2]
Optional cable protection (shortened)