Appliance description
www.bora.com
Residual heat indicator
i
While
H
is displayed (residual heat indicator), do not
touch the cooking zone or place any heat-sensitive
objects on top of it. Risk of burns and fire!
After switching it off, the cooking zone remains hot.
H
is displayed (Residual heat indicator).
After a sufficient cooling period the indicator will go out
(Temperature < 60°C).
Overheating protection
i
If the cooktop overheats, the power is reduced or the
cooktop is switched off completely.
The appliance is fitted with overheating protection. The
overheating protection can be triggered if:
X
O
cookware is heated up empty;
X
O
oil or fat is heated on high power;
X
O
a hot cooking zone is switched on again after a power cut.
Whilst the overheating protection is active, one of the following
steps is taken:
X
O
the activated power setting is switched back to the previous
level;
X
O
the power setting
ßp
can no longer be switched on;
X
O
the set power level is reduced;
X
O
the cooktop switches off completely.
After a sufficient cooling period, the cooktop can be used again.
Childproofing feature
i
If a single cooktop is operated without a cooktop
extractor, removal of the knob ring can prevent the
appliance from being switched on accidentally or without
permission.
Suitable cookware is made of:
X
O
copper
X
O
stainless steel
X
O
aluminium
X
O
cast iron
X
X
Adhere to the dimensions in the table:
Burner position
Recommended pan
diameter
Minimum pan
diameter
Normal burner
140–200 mm
120 mm
High-power burner
180–240 mm
160 mm
Tab. 4.3
Pan diameters
i
Only use cookware with a diameter that is within the
given dimensions (see the Suitable cookware chapter). If
the diameter is too large, the hot gases flowing outwards
from under the base may damage the worktop or any
non-heat-resistant wall, e.g. with panelling, as well as
part of the cooktop and the cooktop extractor. Bora shall
not be held liable for any such damage.
4.3 Safety devices
Safety shut-down
If an appliance is switched on but is not used for a predefined
time, it is automatically switched off.
Cooktops
Each cooking zone is switched off automatically when the cooking
zone exceeds the maximum operating duration on one power level
or heat retention level.
H
is displayed (Residual heat indicator).
PKG3:
Power levels Safety shut-down after hours:minutes
1
8:24
2
6:24
3
5:12
4
4:12
5
3:18
6
2:12
7
2:12
8
1:48
9
1:18
ßp
0:20
Tab. 4.4
Safety shut-down on the different power levels
PKG3:
Heat retention level
Switch off after hours:minutes
1 (
, v
)
8:00
2 (
: v
)
8:00
3 (
* v
)
8:00
Tab. 4.5
Safety shut-down on the different heat retention levels
X
X
Switch the cooking zone back on if you want to put the
cooking zone back into operation (see the Operation chapter).