Installation
www.bora.com
min. 700*
min. 74
176
900
(min.
890)
**
120
252
285
min.
100
170
682
max. 562
max. 430
389*
110
PKA3 mit Flachschalldämpfer USDF, Flachkanalverbinder
EFV und Übergangsstück Versatz EFRV110 (Zeile):
PKA3 mit Rundschalldämpfer USDR50 und Rundkanal-
verbinder ERV (Insel):
PKAS3 mit Ecotube Flachkanal:
PKA3 mit Flachschalldämpfer USDF, Flachkanalverbinder
EFV und Übergangsstück gerade EFRG (Insel):
min. 700
min. 74
199
min.
100
120
691
min. 455
58
min. 328
max. 580
592
152
min. 810*
min. 74
176
900
(min.
890)
**
220
min.
100
110
760
max. 545
219*
151*
BORA Professional 3.0
B O R A L Ü F T U N G S F I B E L
XX
min. 810*
min. 74
176
900
(min.
890)
**
120
min.
100
93
min. 742
max. 562
219*
151*
295
33
180
810
Fig. 5.3
Appliance installation dimensions for standard set-up
of PKA3/PKA3AB with round silencer USDR50
5.4.3 Worktop and kitchen units
X
X
Create the worktop cut-out taking into account the specified
cut-out dimensions.
X
X
Make sure that the cut surfaces of the worktops are properly
sealed.
X
X
Comply with the instructions of the worktop manufacturer.
X
O
Cross bars on the kitchen unit in the area of the worktop cut-
out may need to be removed.
X
O
No false floor is necessary below the cooktop. If cable
protection (false floor) is planned, the following must be taken
into account:
X
O
it must be fitted in such a way that it can be removed for
maintenance work;
X
O
to ensure sufficient cooktop ventilation, a minimum
distance of 15 mm to the bottom edge of the cooktop is
to be observed.
X
O
The drawers and/or shelves in the floor unit must be
removable.
X
O
For correct installation, the drawers of the floor unit must be
shortened depending on the installation situation.
5.4 Assembly instructions
5.4.1 Safety clearances
X
X
Maintain the following safety clearances:
1
3
2
Fig. 5.1
Minimum distance
[1]
Minimum clearance of 50 mm at the back from the worktop
cut-out to the rear edge of the workto
[2]
Minimum clearance of 300 mm from the left and right of the
worktop cut-out to the adjacent cabinet or wall.
[3]
Minimum clearance of 650 mm between the worktop and the
wall unit.
5.4.2 Minimum installation dimensions
(standard set-up)
≥810
≥890
≥900
Fig. 5.2
Minimum installation dimensions for standard set-up
of PKA3/PKA3AB