bora PKA1UMEN-001 Operating And Installation Instructions Download Page 4

EN

4

General information

www.bora.com

1  General information

Target group

These operating and installation instructions apply for the 

following target groups:

Target group

Requirements

User

The appliance can be used by children 

aged 8 and above as well as people with 

reduced physical, sensory or mental 

capacities or a lack of experience and/or 

knowledge if they are supervised or have 

been instructed how to safely use the 

appliance and understand the resultant 

risks. Children must be supervised. All 

safety and warning information and the 

handling instructions in the installation 

instructions must be complied with.

Ambitious DIYers

Ambitious DIYers can independently 

conduct all joinery and installation work 

providing they possess the necessary 

skills and expertise. They must never 

independently establish electricity and 

gas connections.

Installation specialists Installation specialists are authorised 

to conduct all joinery and installation 

work in line with existing regulations. The 

electricity and gas connections must be 

certified by a certified engineer for the 

applicable trade prior to commissioning.

Electricians

The electrical connection may only be 

 established by a certified engineer.  

He/she also assumes responsibility for 

the proper electrical installation and 

commissioning.

Gas specialists

The gas connection may only be 

 established by certified engineers.  

They also assume responsibility for 

 proper installation and commissioning of 

the gas system.

Tab. 1.1  Target groups

INFO

 

BORA Holding GmbH, BORA Vertriebs GmbH 

& Co KG, BORA APAC Pty Ltd and BORA 

Lüftungstechnik GmbH - hereinafter referred 

to as BORA - do not assume any liability for 

damage arising from non-adherence to these 

documents and from improper assembly! The 

electricity and gas connections must be made 

by a qualified specialist. Installation must 

 comply with the valid standards, regulations 

and laws. All safety and warning information 

and the operating and installation instructions 

must be complied with.

Validity of the operating and 

installation instructions

These instructions apply to several device versions. It is 

therefore possible that some of the features described do 

not apply to your appliance.

Other applicable documents

These operating and installation instructions are valid 

in conjunction with other documents, which must be 

adhered to.

Please be sure to adhere to all documents that form part 

of the scope of delivery.

INFO

 

BORA accepts no liability for damage caused 

by failure to comply with these documents!

Directives

These devices meet the following EU/EC directives:

2014/30/EU EMC Directive 

2014/35/EU Low Voltage Directive 

2009/125/EC Ecodesign Directive 

2010/30/EU Energy Consumption Label Directive

2011/65/EU RoHS Directive

2012/19/EU WEEE Directive

Summary of Contents for PKA1UMEN-001

Page 1: ...EN PKA1UMEN 001 www bora com Operating and installation instructions PKA PKAS Cooktop extractor 1039946...

Page 2: ...of its contents are prohibited unless expressly authorised These operating and installation instructions have been drawn up with the greatest of care But it cannot be ruled out that subsequent techni...

Page 3: ...installation 24 6 8 2 Connect the duct system to the device 25 6 8 3 Standard setup PKA 25 6 8 4 Installing the additional fan 25 6 9 Operating the cooktop extractor with a fireplace that depends on t...

Page 4: ...nd commissioning Gas specialists The gas connection may only be established by certified engineers They also assume responsibility for proper installation and commissioning of the gas system Tab 1 1 T...

Page 5: ...hted with symbols and signal words Safety and warning information is structured as follows WARNING SYMBOL AND SIGNAL WORD Type and source of the danger Consequences of non compliance X X Measures to m...

Page 6: ...use with BORA gas cooktops X X Switch the device off after use X X Keep pets away from the appliance Recirculation mode INFO When cooking additional moisture is released into the ambient air INFO In...

Page 7: ...t use steam cleaners The steam can cause a short circuit on live parts and cause damage to property see Cleaning and maintenance section X X Make sure no water penetrates inside the device when cleani...

Page 8: ...ripping lengths are adhered to X X Check the appliance for visible damage before installing it X X Do not install damaged devices Q Q A damaged device is a hazard Q Q Repair work must only be carried...

Page 9: ...ctions disassembly and disposal The device must only be disassembled by trained specialists who are familiar with and comply with the standard national regulations and supplementary regulations of the...

Page 10: ...x 176 mm Dimension of control knob diameter x depth 49 mm 92 mm Weight incl accessories packaging 9 25 kg Cooktop extractor Power levels 1 9 P Tab 3 1 Technical data PKA Device dimensions PKA 110 482...

Page 11: ...n including external BORA universal article fans max 700 W Power consumption of internal motor max 170 W Dimensions width x depth x height 468 x 540 x 199 mm Dimension of control knob diameter x depth...

Page 12: ...8 91 28 61591 Class maximum level B B 61591 Sound power level minimum 42 5 dB A 47 6 dB A 60704 2 13 maximum 61 5 dB A 68 4 dB A 60704 2 13 Power setting 61 8 dB A 69 9 dB A 60704 2 13 Sound pressure...

Page 13: ...o a smoke or exhaust gas flue that is not in use the installation must be checked and approved by the responsible heating engineer Recirculation mode The air extracted is purified by the grease filter...

Page 14: ...of functions 2 Power display 3 Recirculation display 4 Display of mode or operating mode 5 Exhaust mode display Control knob display Meaning 1 9 Power levels P Power setting 0 Cooktop extractor is sw...

Page 15: ...ctional principle of the cooktop extractor 5 4 1 Power control The power levels are controlled by turning the knob ring to the desired power level 5 4 2 Power setting The cooktop extractor has a power...

Page 16: ...ructions Scope of delivery PKA Name Quantity Operating and installation instructions 1 Cooktop extractor 1 Height adjustment plate set 1 Mounting clamps 4 Control knob 1 Stainless steel grease filter...

Page 17: ...imum clearance of 600 mm between the worktop and the wall unit 6 4 Cut out dimensions Preparing the worktop X X Create the worktop cut out X X Make sure that the cutting surfaces are properly sealed X...

Page 18: ...sition the cooktop extractor 2 Cut out dimensions when installing cooktops only or cooktops and the cooktop extractor next to each other Cooktops cooktop extractor A in mm B in mm 1 0 374 346 2 0 745...

Page 19: ...thickness X X If necessary shorten the mounting clamps in line with the worktop thickness X X To do this cut the mounting clamps at the appropriate cut marks using a cutter 1 2 Fig 6 10 Height adjust...

Page 20: ...ece 265 Fig 6 18 PKA duct connection dimensions with straight ducting piece X X Depending on the installation type twist the mounting clamps to the left or right flush mounting or surface mounting Sec...

Page 21: ...top 3x 4 Cooktop extractor 2x 5 Worktop 6 Cover for the floor unit 6 6 2 Fitting the control knob 3 2 1 Fig 6 23 Structure of control knob 1 Knob casing 2 Universal nut 3 knob ring 245 77 5 89 151 4 F...

Page 22: ...hole in the panel from the front X X Screw the universal nut 2 onto the knob casing 1 from the rear and tighten a little X X Use the marking to align the knob casing 1 vertically in the 12 o clock pos...

Page 23: ...olding clamps 18x with a screwdriver 2 1 Fig 6 27 Mounting the straight ducting piece 1 Straight ducting piece 2 Ducting piece adapter X X Push the straight ducting piece 1 onto the ducting piece adap...

Page 24: ...the cover frame 1 back on the cooktop extractor 2 X X Make sure that the holding clamps slot into place 6 8 Installing the duct system 6 8 1 Preparing for installation INFO The floor unit must not be...

Page 25: ...extractor system 6 9 Operating the cooktop extractor with a fireplace that depends on the air in the room INFO The state and regional laws and regulations must be observed with regard to the exhaust...

Page 26: ...ation correct X X If simultaneously operating both a fireplace and the cooktop extractor in the same room ensure that Q Q the maximum low pressure is 4 Pa 4 x 10 5 bar Q Q a safety device e g window c...

Page 27: ...re to the connection diagram when connecting Home In and Home Out 1 2 4 3 Fig 6 39 Open the universal control unit s cover 1 Cover 2 Electronic unit 3 Base unit 4 Switch contact terminals INFO The ele...

Page 28: ...trol knob with connection 1 Control knob connection Home In Home Out X 7 1 X 7 2 X 6 1 X 6 2 Fig 6 42 Connection diagram for the external switch contacts X X Connect the cable for the relevant contact...

Page 29: ...le 8 Power supply cable with microfuse X X Use the CAT 5 communication cable to connect the connection for the control unit on the cooktop extractor to the connection on the universal control unit 1 2...

Page 30: ...nth fan 1 Connection plug of the plinth fan power supply cable 2 Connection plug of the plinth fan control line X X Connect the plinth fan s control line 2 to the universal control unit X X Connect th...

Page 31: ...s 6 12 3 Changing the setting X X Turn the knob ring clockwise to increase the value X X Turn the knob ring anticlockwise to decrease the value X X Press the touch surface on the control knob again fo...

Page 32: ...then goes out with a beep INFO If no settings are changed in a menu or sub menu option for 2 minutes the configuration menu is closed automatically 6 13 Handover to user Once installation is complete...

Page 33: ...g drafts 7 2 1 Switching on the cooktop extractor Fig 7 2 Switching on the cooktop extractor X X Turn the knob ring from the 12 o clock position to the power level you want The knob clicks in at the d...

Page 34: ...5 minutes touch the touch operated area for 1 second 7 3 Note the filter service function If a flashing F is shown on the control knob display after switching on the cooktop extractor the service life...

Page 35: ...rmation provided in the Cleaning section X X Replace the activated charcoal filter X X Clean the grease filter Resetting the filter service display If the activated charcoal filter has been replaced a...

Page 36: ...pads or chemically aggressive cleaning agents e g oven cleaner spray X X Make sure that the cleaning agent does not contain any sand soda acids lyes or chloride 8 2 Cleaning the cooktop extractor Gre...

Page 37: ...adjacent 2nd extractor adjacent wok cooktop INFO To remove the maintenance tray the grease filter and the filter tray must first be removed 2 1 Fig 8 5 Removing the maintenance tray 1 Maintenance tra...

Page 38: ...carefully X X Place the knob ring back on the knob housing INFO If the knob ring has not been fitted correctly a segment rotating clockwise is displayed in the central control knob display 8 2 5 Fitti...

Page 39: ...the duct system INFO Regularly replace the activated charcoal filter The service life can be found in the operating instructions for the relevant activated charcoal filter INFO You can obtain activate...

Page 40: ...ivated charcoal filter service life expired Replace the activated charcoal filter clean the stainless steel grease filter if necessary reset the filter timer see Cleaning or Operation section Control...

Page 41: ...ndly disposal 10 3 Environmentally friendly disposal Disposal of transport packaging INFO The packaging protects the device from damage in transport The packaging materials have been selected from env...

Page 42: ...800 7890 0987 X X If there are faults which you are not able to resolve yourself please contact your BORA specialist supplier or the BORA Service Team The BORA Service Team requires the type designat...

Page 43: ......

Page 44: ...Austria T 43 0 5373 62250 0 F 43 0 5373 62250 90 mail bora com www bora com Europe BORA Holding GmbH Prof Dr Anton Kathrein Stra e 3 6342 Niederndorf Austria T 43 0 5373 62250 0 F 43 0 5373 62250 90...