![bora PKA1UMEN-001 Operating And Installation Instructions Download Page 30](http://html1.mh-extra.com/html/bora/pka1umen-001/pka1umen-001_operating-and-installation-instructions_2788189030.webp)
EN
30
Installation
www.bora.com
6.12 Configuration menu
Once installation is complete, you must configure
certain basic settings for your cooktop extractor (see
also the supplementary information sheet on initial
commissioning).
6.12.1 Accessing the configuration menu
X
X
Turn the knob ring from the 12 o-clock position to the
11 o’clock position.
Q
Q
A0 appears in the control knob display.
X
X
Now press the touch surface for 5 seconds.
Q
Q
This accesses the configuration menu and
C
is shown
on the control knob display.
6.12.2 Select menu option
X
X
Turn the knob ring to select the menu option you want.
The following menu options are available:
Display Menu option
C 0
Volume of warning beep
C 1
Select operating mode
(demo mode)
C 2
Speed of cover flap motors
C 3
Selection of filter unit
C4
Exhaust air and/or recirculation
(summer or winter mode)
No current function
C 5
Operation with/without wall sleeve
C 6
Manual operation of cover flap
motors
for BORA Service
Technicians only
C 7
Switchover of PWM values for
PKA/PKAS fan
for BORA Service
Technicians only
Tab. 6.6 Menu options in the configuration menu
X
X
Touch the touch surface on the control knob again for
1 second to confirm the menu you want.
Q
Q
The sub-menu is accessed and the display switches to
a three-character combination (e.g.
C23
).
INFO
In the three-character combination shown, the
right-hand figure shows the value saved in the
system.
2
1
Fig. 6.49 Connection plug of the plinth fan
[1]
Connection plug of the plinth fan power supply cable
[2]
Connection plug of the plinth fan control line
X
X
Connect the plinth fan’s control line [2] to the universal
control unit.
X
X
Connect the plinth fan’s power supply cable [1] to the
universal control unit .
Release the power supply cable
To release the power supply cable for the fan [1] from
the universal control unit [6] you need a small flat
screwdriver.
X
X
Disconnect the universal control unit’s power supply
cable from the power supply [8].
X
X
Make sure that there is no power to the appliance.
X
X
Use the flat screwdriver to loosen the lock on the fan
power supply cable plug.
X
X
To do this, insert the flat screwdriver into the gap in
the socket.
X
X
Press the lock down gently.
X
X
Use the flat screwdriver to gently lever the plug of the
power supply cable out of the universal control unit’s
socket.
X
X
Now disconnect the power supply cable from the
socket.
X
X
Check the plug and the socket for damage.
X
X
Do not use damaged components.
X
X
Contact your BORA specialist supplier to replace any
damaged components.
Connecting the additional fan
X
X
Connect the fan control line [2] to the universal control
unit [5].
X
X
Connect the fan mains connection line [1] to the
universal control unit [7].
X
X
Check all the plug connections to ensure that they are
secure.
6.11.4 Establishing the power connection
X
X
Connect the mains connection line for the extraction
system (PKAS) or the mains connection cable for the
universal control unit (PKA) to the power supply.
X
X
Put the cooktop extractor into operation
(see the Operation section).
X
X
Check that all the functions are working correctly.