bora CKCB Installation Instructions Manual Download Page 4

EN

4

General information

www.bora.com

1  General information

1.1  Target group

These installation instructions apply to the following 

target groups:

Target group

Requirements

Ambitious DIYers

Ambitious DIYers can independently 

conduct all joinery and installation work 

providing they possess the necessary 

skills and expertise. They must never 

independently establish electricity and 

gas connections.

Installation specialists Installation specialists are authorised 

to conduct all joinery and installation 

work in line with existing regulations. 

The electricity and gas connections must 

be certified by a certified engineer from 

the applicable specialist field prior to 

commissioning.

Electricians

The electrical connection may only be 

established by a certified engineer. He/

she also assumes responsibility for 

the proper electrical installation and 

commissioning.

Qualified gas 

technicians

The gas connection may only be 

established by a certified tradesperson. 

He/she also assumes responsibility 

for the proper gas installation and 

commissioning.

Tab. 1.1  Target groups

INFO 

BORA Holding GmbH, BORA Vertriebs GmbH 

& Co KG, BORA APAC Pty Ltd and BORA 

Lüftungstechnik GmbH – hereinafter referred to 

as BORA – do not assume any liability for damage 

arising from disregard for or non-adherence to 

these documents and improper installation! The 

electricity and gas supply must be connected 

by a certified specialist. Installation may only 

be carried out in accordance with the applicable 

standards, regulations and laws. All safety and 

warning information, as well as the handling 

instructions in the operating and installation 

instructions must be observed.

1.2  Validity

These instructions apply to several appliance versions. It 

is therefore possible that some of the features described 

do not apply to your appliance. The details of the figures 

contained herein may differ from some appliance versions 

and are to be understood as schematic diagrams.

1.3  Other applicable documents

These instructions are valid in conjunction with other 

documents, which must be adhered to.

Please by all means adhere to all documents that form 

part of the scope of delivery.

INFO 

BORA do not assume any liability for damage 

arising from non-adherence to these documents.

Directives

The appliances meet the following EU/EC directives:

2014/30/EU EMC Directive 

2014/35/EU Low Voltage Directive 

2009/125/EC Ecodesign Directive 

2011/65/EU RoHS Directive

2012/19/EU WEEE Directive

Cooktop extractors also meet the following EU/EC 

directives:

2010/30/EU Energy Labelling Directive

Regulations

Gas appliances meet the following EC directives:

(EU) 2016/426 regulation on appliances burning gaseous 

fuels

1.4  Data protection

During operation your cooktop extractor saves 

pseudonymised data such as menu settings entered by 

you, operating hours of the individual technical units and 

the number of functions selected. Furthermore, your 

cooktop extractor documents errors in combination with 

the number of operating hours.

The data can only be read manually via your cooktop 

extractor, thus the decision is yours.

The saved data then enable a rapid error search and 

troubleshooting in case of service.

Summary of Contents for CKCB

Page 1: ...EN C2XIMEN 001 www bora com BORA Classic 2 0 system installation instructions Cooktop extractor and cooktops...

Page 2: ...ontents are prohibited unless expressly authorised Great care was taken when devising these operating and installation instructions However it may be the case that later technical changes or adaptatio...

Page 3: ...9 4 7 Installation options 20 4 8 Assembling the extraction system 20 4 8 1 Assembling cooktop extractor CKA2 21 4 9 Installing the cooktop extractor 21 4 9 1 Fitting and positioning the cooktop extra...

Page 4: ...tandards regulations and laws All safety and warning information as well as the handling instructions in the operating and installation instructions must be observed 1 2 Validity These instructions ap...

Page 5: ...asised with symbols and signal words Safety and warning instructions are structured as follows WARNING SYMBOL AND SIGNAL WORD Type and source of danger Results of non compliance X X Measures to minimi...

Page 6: ...contact with hot cooking surfaces is not possible X X Do not place any objects on the operating panel or the cooktop extractor air inlet nozzle X X Switch off the appliance after use X X Keep pets aw...

Page 7: ...unit can lead to a short circuit X X Do not operate any appliance with a damaged operating unit X X Inform a BORA Service technician and have the operating unit replaced 2 2 1 Safety instructions coo...

Page 8: ...GmbH BORA Vertriebs GmbH Co KG BORA APAC Pty Ltd and BORA L ftungstechnik GmbH do not assume any liability for damage arising from non adherence to the safety and warning information Special safety i...

Page 9: ...190 mm Weight incl accessories packaging 7 5 kg Surface material SSG glass 1 4301 stainless steel and plastic Cooktop extractor Power levels 1 5 P Connection on the exhaust side BORA Ecotube Tab 3 1...

Page 10: ...e protection 1 x 16 A Dimensions width x depth x height 327 x 515 x 58 mm Weight incl accessories packaging 7 9 kg Cooktop Power levels 1 9 P Heat retention levels 3 Front cooking zone zone 1 power se...

Page 11: ...wer consumption 3 68 kW Fuse protection 1 x 16 A Dimensions width x depth x height 327 x 515 x 58 mm Weight incl accessories packaging 7 6 kg Cooktop Power levels 1 9 P Heat retention levels 3 Front c...

Page 12: ...50 32 5 Fig 3 13 CKIW device dimensions side view 3 4 CKIW Parameter Value Supply voltage 220 240 V Frequency 50 60 Hz Power consumption 3 0 kW Fuse protection 1 x 16 A Dimensions width x depth x heig...

Page 13: ...tion 3 68 kW Fuse protection 1 x 16 A Dimensions width x depth x height 327 x 515 x 75 mm Weight incl accessories packaging 7 2 kg Cooktop Power levels 1 9 P 2 ring additional switching Warming levels...

Page 14: ...1 x 16 A Dimensions width x depth x height 327 x 515 x 75 mm Weight incl accessories packaging 7 4 kg Cooktop Power levels 1 9 2 ring connection roaster cooking zone connection Heat retention levels 3...

Page 15: ...CKT Parameter Value Supply voltage 220 240 V Frequency 50 60 Hz Power consumption 3 5 kW Fuse protection 1 x 16 A Dimensions width x depth x height 327 x 515 x 73 mm Weight incl accessories packaging...

Page 16: ...ould be drawn out of the chimney or extraction ducting and back into the room Fig 4 1 Exhaust air installation not permitted Fig 4 2 Exhaust air installation correct X X If simultaneously operating bo...

Page 17: ...s Worktop overhang 50 x Fig 4 4 Worktop overhang X X Please note the worktop overhang x when creating the worktop cut out 4 2 2 Scope of delivery of the cooktops Scope of delivery CKFI CKI CKIW CKCH C...

Page 18: ...5 Tab 4 4 Cut out dimensions of the appliance combinations in the case of surface mounting 4 5 1 Flush installation x A 2 B 2 519 2 R 5 R 5 50 50 495 2 600 Fig 4 5 Cut out dimensions for flush install...

Page 19: ...a unit depth of 600 mm min 100 max 580 495 min 700 min 50 max 440 530 219 151 min 900 190 290 120 Fig 4 12 Appliance installation dimensions with shallow silencer USDF in case of a unit depth of 700 m...

Page 20: ...the parts together Q Q If not aligned correctly the parts cannot be assembled easily solve this by turning or rotating the part X X Make sure that all locks click into place min 100 max 460 495 674 m...

Page 21: ...he appliances Q Q Cross bars on the kitchen unit in the area of the worktop cut out may need to be removed Q Q The drawers and or shelves in the floor unit must be removable for maintenance and cleani...

Page 22: ...piece is created when the seals are compressed Q Q The maximum exhaust air duct length with a fan is 6 m Q Q The minimum cross section of the air ducts must be 176 cm which equates to a round pipe wi...

Page 23: ...utlet nozzle X X Push the seal onto the plinth fan outlet nozzle The seal will need to be stretched slightly Connecting the duct system 2 2 3 1 Fig 4 23 Duct system connection 1 Output nozzles 2 Seal...

Page 24: ...ected correctly The system configuration is adjusted accordingly 4 11 Installing the cooktops INFO Clearance of one millimetre should be planned between the appliances INFO In the case of flush instal...

Page 25: ...ting brackets 1 X X To do this tighten the mounting brackets with a screw 3 using the washers 2 with max 2 Nm X X Do not use a cordless screwdriver or similar electrical device to secure the cooktops...

Page 26: ...interrupt the control unit power supply phase separation Only the built in interface is to be used Preparing the control unit 1 2 3 4 5 Fig 4 30 Opening the control unit housing cover 1 Housing cover...

Page 27: ...t to the switch contact clamp in accordance with the connection diagram Q Q In order to connect the Home In interface the installed bridge must be removed INFO The Home In contact must be bridged if t...

Page 28: ...onnection 13 Home In connection 14 Home In connection cable 15 External device 16 Power supply cable for external device M Fan 2 S1 External switch contact 4 13 1 Establishing contact between the cook...

Page 29: ...length of the power supply cable 1 m 4 13 6 Connecting to the mains X X Observe all safety and warning information see the Safety chapter X X Observe all national and regional laws and regulations as...

Page 30: ...uration 4 14 1 Basic configuration INFO When using for the first time the system must be configured It is absolutely essential to go through the three menu items of the basic configuration from start...

Page 31: ...the configuration is adjusted accordingly During initial operation it is necessary for the installer to check that the fans have been recognised correctly Starting fan configuration Fig 4 43 Starting...

Page 32: ...icone sealant 1 Fig 4 45 Silicone sealant for surface mounting 1 black heat resistant silicone sealant X X Once all of the installation work and initial operation is complete seal the devices with bla...

Page 33: ...t packaging INFO The packaging protects the device from damage in transport The packaging materials have been selected from environmental and disposal perspectives and are therefore recyclable Returni...

Page 34: ...EN 34 Notes www bora com 6 Notes...

Page 35: ...EN 35 Notes www bora com...

Page 36: ...dorf Austria Tel 43 0 5373 62250 0 Fax 43 0 5373 62250 90 mail bora com www bora com Europe BORA Holding GmbH Innstra e 1 6342 Niederndorf Austria Tel 43 0 5373 62250 0 Fax 43 0 5373 62250 90 mail bor...

Reviews: