Installation
www.bora.com
4.13.3 Establishing contact between the
operating unit and control unit
1
Fig. 4.37 Socket for the CAT 5 communication cable on the
operating unit
1
2 3
4
5
6
Fig. 4.38 Control unit connections
[1]
CAT 5 communication cable socket
[2]
Control unit port for fan 1
[3]
Control unit port for fan 2
[4]
Power supply cable port for fan 1
[5]
Power supply cable port for fan 2
[6]
Power supply cable socket with micro fuse
X
X
Using the CAT 5 communication cable (included in
the scope of delivery) link the connections [1] on the
operating unit to the control unit.
INFO
The operating unit is controlled by and receives its
power supply via the CAT 5 communication cable.
4.13.4 Connecting fans to the control unit
2
1
Fig. 4.39 Fan connection plug
[1]
Fan power supply cable connection plug
[2]
Fan control line connection plug
X
X
Connect the fan control line [2] to the control unit.
X
X
Connect the fan power supply cable [1] to the control unit.
Q
Q
When connecting the fan control line and power supply
cable it does not matter if you use socket 1 or 2 on the
control unit.
4.13.5 Positioning the control unit
INFO
The control unit must be placed inside the kitchen
unit.
Permissible positioning options:
Q
Q
loose on a false floor
Q
Q
loose on the shallow duct
Q
Q
mounted on the kitchen unit
INFO
When positioning the control unit please observe
the length of the power supply cable (1 m).
4.13.6 Connecting to the mains
X
X
Observe all safety and warning information (see the
Safety chapter).
X
X
Observe all national and regional laws and regulations
as well as the supplementary regulations of the local
utility companies.
INFO
The power connection may only be established by
certified specialists. The specialist also assumes
responsibility for the proper installation and
commissioning.
Special information for CKT:
INFO
The Classic Tepan stainless steel grill CKT is
intended to be operated on a supply network with
an impedance Zmax at the transfer point (mains
connection) of 0.1779 ohms maximum. The user
is to ensure that the appliance is only operated
on a mains supply network which meets this
requirement. If necessary, ask the local energy
supply company about the system impedance.
Cooktop power connection
The power supply cable to be used (pre-assembled) must
be at least Type H05VV-F.
Connection
Fuse protection Minimum cross-section
1-phase connection
1 x 16 A
1.5 mm
²
Tab. 4.7 Fuse protection and minimum cross-section
INFO
A damaged power supply cable must be replaced
by a suitable power supply cable. This may only
be done by an authorised member of the After
Sales Service team.
X
X
Switch off the main switch/automatic circuit breaker
before connecting the cooktop.
X
X
Secure the main switch/automatic circuit breaker
against being switched back on without permission.
X
X
Make sure the power to the appliance is disconnected.
X
X
Only connect the cooktop using a fixed connection to
the mains voltage.