Installation
www.bora.com
Fig. 4.14 Airflow towards the rear (right or left)
Fig. 4.15 Straight airflow towards the side (right or left)
4.8 Assembling the extraction system
INFO
Cooktop extractor CKA2 is delivered as individual
parts which must be assembled prior to or during
installation.
INFO
The individual components must be assembled
according to the installation option.
INFO
All individual components are built in such a way
that they can be assembled without any difficulty.
The parts can only be assembled correctly and
without applying force if they are aligned correctly.
X
X
Assemble the individual parts as required for the
planned installation option.
X
X
Make sure that the parts are aligned correctly.
X
X
Do not force the parts together.
Q
Q
If not aligned correctly, the parts cannot be assembled
easily (solve this by turning or rotating the part).
X
X
Make sure that all locks click into place.
min. 100
max. 460
495
674
min. 50
569
219
151
min. 870
190
256
min. 720
Fig. 4.13 Appliance installation dimensions with round silencer
USDR50
4.7 Installation options
INFO
The BORA Classic 2.0 system offers different
installation options. It is necessary to decide
which installation option is to be implemented
prior to installation.
X
X
Please ensure prior to installation that you have
made the correct preparations for the corresponding
installation.
X
X
In the event of any queries regarding the planned
installation option, please contact your kitchen planner.
Installation option overview
INFO
The installation options shown below can be fitted
on the right or left-hand side.
The following airflow options can be implemented with
the BORA Classic 2.0 system: