bora CG11 Operating And Installation Instructions Download Page 10

EN

10

Safety

www.bora.com

Cooktop

 DANGER!

Risk of electric shock!

Incorrect connection of the device 

to the mains voltage could cause 

 electric  shocks.

X

X

Make sure that the device is firmly 

connected to the mains voltage.

X

X

Make sure the device is connected 

to a properly installed earth 

 conductor system.

X

X

Make sure a system is installed 

which allows disconnection from 

the network with a contact 

 opening width of at least 3 mm 

 across all poles (circuit breaker, 

fuses, automatic circuit breakers, 

contactors).

 DANGER!

Risk of electric shock!

If the mains connection cable comes 

into contact with hot hobs, it could 

get damaged. A damaged mains 

 connection cable can cause a  

(deadly) electric shock.

X

X

Make sure that the mains 

 connection cable cannot come 

into contact with hot hobs.

X

X

Make sure that the connection 

cable is not squashed or damaged.

 DANGER!

Risk of explosion from gas!

Gas leaks can cause explosions and 

serious injuries.

X

X

Keep ignition sources (naked 

 flames, heaters) away.

X

X

Close the gas supply and switch 

the building supply off.

X

X

Close any leaks immediately.

 CAUTION!

Lifting heavy loads can cause back 

injuries!

If not correctly handled, removing 

and installing the device can causes 

injuries to the limbs or torso.

X

X

Removing the cooktop from the 

packaging is a two-person job.

X

X

Placing the cooktop into the 

worktop cut-out is a two-person 

job.

X

X

Use appropriate aids to prevent 

 damage or injuries to limbs or 

 torso.

X

X

Check the appliance for visible damage 

 before installing it.

X

X

Do not install damaged devices. 

Q

Q

A damaged device is a hazard.

Q

Q

Repair work must only be carried out by 

specialists authorised by the manufacturer.

2.4  Safety instructions – 

disassembly and disposal

The device must only be disassembled by 

 trained specialists who are familiar with and 

comply with the standard national regulations 

and supplementary regulations of the local 

 utility  companies. 
Work on electrical components must only be 

conducted by trained electrical personnel.
Work on the gas connection may only be 

carried out by an authorised gas fitter in 

 accordance with applicable legal regulations. 

Comply with the local regulations of the utility 

companies.

 

 DANGER!

Risk of electric shock!

Incorrectly disconnecting the 

 appliance from the mains results in a 

risk of electric shock.

X

X

Securely disconnect the appliance 

from the mains using LS switches, 

fuses, automatic circuit breakers 

or contactors.

X

X

Use an authorised measuring 

 device to ensure that there is no 

power to the appliance.

Summary of Contents for CG11

Page 1: ...AU Operating and installation instructions CG11 Gas glass ceramic cooktop with 2 cooking zones CG11UMAU 002 www bora com VB2VRAM0G0NNGQ2...

Page 2: ...of its contents are prohibited unless expressly authorised These operating and installation instructions have been drawn up with the greatest of care But it cannot be ruled out that subsequent techni...

Page 3: ...dover to user 18 6 Gas installation 19 6 1 Ventilation 19 6 2 Gas connection 19 6 2 1 Additional installation notes for Australia and New Zealand AUS NZS 20 6 2 2 Gas connection AUS NZS 20 6 3 Leak te...

Page 4: ...ion and commissioning Gas specialists The gas connection may only be established by certified engineers They also assume responsibility for proper installation and commissioning of the gas system Tab...

Page 5: ...hted with symbols and signal words Safety and warning information is structured as follows WARNING SYMBOL AND SIGNAL WORD Type and source of the danger Consequences of non compliance X X Measures to m...

Page 6: ...ce X X Do not use this appliance as a space heater CAUTION Risk of injury from falling device components Falling device components such as pan supports control elements covers grease filters etc can c...

Page 7: ...nd switch the building supply off X X Keep children and other people away from hot hobs Unauthorised modifications Unauthorised modifications can cause the appliance to pose risks X X Do not conduct a...

Page 8: ...n base can evaporate and cause burns X X Make sure that the cooking zone and the pan base are always dry DANGER Risk of asphyxiation as a result of a gas leak Gas leaks can cause asphyxiation X X If y...

Page 9: ...p CAUTION Risk of injury due to the glass ceramic panel being fissured cracked or broken A damaged glass ceramic surface can cause injuries X X Do not touch the appliance surface X X Immediately switc...

Page 10: ...d removing and installing the device can causes injuries to the limbs or torso X X Removing the cooktop from the packaging is a two person job X X Placing the cooktop into the worktop cut out is a two...

Page 11: ...a level The device is designed exclusively for the preparation of food in private households This appliance is not intended for Q Q Outdoor use Q Q Installation in vehicles Q Q Heating rooms Q Q Use i...

Page 12: ...normal burner 450 1000 W Back high power burner 800 2900 W Total nominal connection values G20 20 mbar 3 90 kW 0 371 m h Total nominal connection values G30 50 mbar 3 80 kW 276 g h Total nominal conn...

Page 13: ...r levels Small flame Minimal gas output Large flame Maximum gas output 0 position No gas output Tab 4 1 Significance of the power levels Knob operation The operating panel is equipped with two control...

Page 14: ...food Activity Power level Keeping cooked meals warm Minimal flame Browning chopped vegetables fried eggs veal poultry Medium flame Grilling prawns corn on the cob schnitzel beef fish or burgers Large...

Page 15: ...ab 5 1 Scope of delivery X X Check the scope of delivery for damage and make sure it is complete see Tab 5 1 X X If there are any missing or damaged parts please notify BORA After Sales Service X X Do...

Page 16: ...tting surfaces of the worktops are properly sealed X X Comply with the instructions of the worktop manufacturer Attaching the sealing tape 1 2 Fig 5 6 Sealing tape with flush installation 1 Black heat...

Page 17: ...erside of the device before installing it Do not leave any gaps with the exception of the side adjacent to the extraction system X X With flush installation attach the enclosed sealing tape to the hor...

Page 18: ...stallation instructions for safe storage For flush installation X X Make sure that the sealing tape of the cooktop is sealed well all the way round 1 3 2 Fig 5 11 Mounting straps 1 Screw 2 Mounting br...

Page 19: ...KAS guideline no 1942 Liquid gas part 2 Regulations of the Vereinigung Kantonaler Feuerversicherungen VKF Netherlands Belgium France Regulations of standard NBN D 51 003 Regulations and connection req...

Page 20: ...tural gas NG If the cooktop is connected to a natural gas NG supply a gas regulator must be installed with a test point The gas regulator and the transition piece are included in the scope of delivery...

Page 21: ...eaker X X Protect the main switch automatic circuit breaker from being switched on without permission X X Make sure the device is not energised 1 Fig 6 1 Connection with gas regulator NG 1 Seal 2 Tran...

Page 22: ...ween the maximum and minimum setting on the gas burner 6 5 Handover to user Once installation is complete X X Explain the main functions to the user X X Explain all safety related aspects of operation...

Page 23: ...2 M 46 M Tab 6 2 Standard nozzle table AUS NZS Gas type LPG liquid gas NG natural gas Peak pressure kPa Gas burner position Nozzle diameter 1 100mm Heat output MJ n G30 butane LPG 2 75 Back 91 10 4 G3...

Page 24: ...ches off the gas supply Q Q No more gas will flow Fig 7 1 Push and pull control knob Ignition When igniting the gas burner the control knob must be kept pressed in after ignition for another approx 15...

Page 25: ...air baffle INFO The cover plate can heat up during use Fig 7 1 The position of the air baffle of the CKASE extraction system X X Before use place both cover plates in the intended positions on the ext...

Page 26: ...glass ceramic cooktops see the Device description chapter 8 3 Cleaning the cooktop INFO When the cooktop extractor is switched on the stainless steel grease filter must be installed to ensure that no...

Page 27: ...ailable detergent by means of a soft sponge or a normal dishcloth Q Q Never scrape or scratch off cooking residues Q Q Do not put the gas burner parts and the pot holder in the dishwasher for cleaning...

Page 28: ...the gas burner head Clean the gas burner parts see the Cleaning chapter You notice the smell of gas A leakage point in the gas supply line Switch off the gas supply and immediately extinguish all open...

Page 29: ...ly disposal 10 3 Environmentally friendly disposal Disposal of transport packaging INFO The packaging protects the device from damage in transport The packaging materials have been selected from envir...

Page 30: ...you are not able to resolve yourself please contact your BORA specialist supplier or the BORA Service Team The BORA Service Team requires the type designation and the build number of your appliance FD...

Page 31: ......

Page 32: ...stria T 43 0 5373 62250 0 F 43 0 5373 62250 90 mail bora com www bora com Europe BORA Holding GmbH Prof Dr Anton Kathrein Stra e 3 6342 Niederndorf Austria T 43 0 5373 62250 0 F 43 0 5373 62250 90 mai...

Reviews: