6.6.1 Using the cooktop extractor with a
fireplace which does not depend on
room air
Fireplaces depending on room air (e.g. gas, oil, wood or
coal-fired heaters, continuous-flow water heaters, instan-
taneous water heaters) draw in air from the room in which
they are installed and discharge the exhaust fumes to the
outside via an exhaust system (e.g. chimney).
When the cooktop extractor is used for exhaust air opera-
tion, it draws in air from the room it is installed in and from
neighbouring rooms. If there is insufficient air, an under-
pressure will occur. Toxic gases could be drawn out of the
chimney or extraction duct and back into the room.
Fig. 6.19 Incorrect exhaust air system installation
Fig. 6.20 Correct exhaust air system installation
X
X
When running the cooktop extractor in the room in
which a fireplace is installed, make sure that
Q
Q
the maximum underpressure is 4 Pa (4 x 10
-5
bar),
Q
Q
a safety-related device (e.g. window contact switch,
minimum pressure controller) ensuring that a suffi-
cient supply of fresh air is guaranteed must always
be used,
Q
Q
the exhaust air may not be ducted into a chimney
that is used for exhaust gases of devices operated
with gas or other combustibles,
Q
Q
the installation has been inspected and signed off
by a qualified professional (e.g. chimneysweep).
X
X
Note the flow direction of the filter. This is indicated
by an arrow.
X
X
Close the cover to the housing [1].
5
4
3
2
1
6
5
1
Fig. 6.18 Securing the cooktop in the middle
[1]
Cooktop
[2]
Suction opening
[3]
Air inlet nozzle
[4]
Stainless steel grease filter
[5]
Worktop cut-out
[6]
Mounting bracket
For surface installation
X
X
Make sure that the sealing tape of the cooktop is rest-
ing on the worktop.
For flush installation
X
X
Make sure that the sealing tape of the cooktop is
sealed well all the way round.
X
X
You may need to place some height adjustment panels
underneath.
X
X
Fasten the cooktop using the mounting brackets [6] at
the worktop.
X
X
Afterwards, insert the stainless steel grease filter [4]
and air inlet nozzle [3].
X
X
Seal the surrounding gap with a black heat-resistant
silicone sealing compound.
6.6 Installing exhaust air duct variant
(BIA)
INFO
National and regional laws and regulations
must be followed when executing the exhaust
air duct.
Sufficient intake air must be provided.