GB
20
Assembly
www.bora.com
Installation dimensions
196
483
760
515
510 - 570
Fig. 6.9 Device dimensions, recirculated air
735
510 - 570
>800
650
>50
119
>25
90
490
>600
90
117
650
675
< R15
133
119
6x Ø5mm
Fig. 6.10 Dimensions of furniture, recirculated air
X
X
With surface installation, attach the included sealing
tape [2] on the underside of the cooktop before install-
ing it. Do not leave any gaps.
X
X
With flush installation, attach the sealing tape [2] to
the horizontal cutting edge in the worktop cut-out,
even if you seal the cooktop with a silicone sealing
compound [1] or similar.
X
X
Align the cooktop precisely.
1
2
Fig. 6.8 Height adjustment plates
[1]
Cooktop
[2]
Height adjustment plates
X
X
If necessary insert height adjustment plates [2].
X
X
Note down the type designation and build number of
the cooktop (FD number) on the back of this manual.
Both designations can be found on the nameplate on
the underside of this cooktop.
6.5 Installing the air recirculation
version (BIU)
INFO
There must be a minimum clearance of 25 mm
for the vertical return flow aperture.
INFO
There must be a return flow aperture of at
least 500 cm
2
.
When the cooktop extractor is exclusively used in recircu-
lated air mode, it is possible to operate it with an open
furnace without any additional safety measures being
required.