background image

EN

4

General information

www.bora.com

1  General information

1.1  Target group

These operating and installation instructions apply for the 

following target groups:

Target group

Requirements

User

The appliance can be used by children 

aged 8 and above as well as people with 

reduced physical, sensory or mental 

capacities or a lack of experience and/or 

knowledge if they are supervised or have 

been instructed how to safely use the 

appliance and understand the resultant 

risks. Children must be supervised. All 

safety and warning information and the 

handling instructions in the installation 

instructions must be complied with.

Ambitious DIYers

Ambitious DIYers can independently 

conduct all joinery and installation work 

providing they possess the necessary 

skills and expertise. They must never 

independently establish electricity and 

gas connections.

Installation specialists Installation specialists are authorised 

to conduct all joinery and installation 

work in line with existing regulations. The 

electricity and gas connections must be 

certified by a certified engineer for the 

applicable trade prior to commissioning.

Electricians

The electrical connection may only be 

 established by a certified engineer.  

He/she also assumes responsibility for 

the proper electrical installation and 

commissioning.

Gas specialists

The gas connection may only be 

 established by certified engineers.  

They also assume responsibility for 

 proper installation and commissioning of 

the gas system.

Tab. 1.1  Target groups

INFO 

BORA Holding GmbH, BORA Vertriebs GmbH 

& Co KG, BORA APAC Pty Ltd and BORA 

Lüftungstechnik GmbH - hereinafter referred to 

as BORA - do not assume any liability for damage 

arising from non-adherence to these documents 

and from improper assembly! The electricity and 

gas connections must be made by a qualified 

specialist. Installation must  comply with the 

valid standards, regulations and laws. All safety 

and warning information and the operating and 

installation instructions must be complied with.

1.2  Validity of the operating and 

installation instructions

These instructions apply to several device versions. It is 

therefore possible that some of the features described do 

not apply to your appliance.

1.3  Other applicable documents

These operating and installation instructions are valid 

in conjunction with other documents, which must be 

adhered to.

Please be sure to adhere to all documents that form part 

of the scope of delivery.

INFO 

BORA accepts no liability for damage caused by 

failure to comply with these documents!

Directives

This device meets the following EU/EC directives:

2014/30/EU EMC Directive 

2014/35/EU Low Voltage Directive 

2009/125/EC Ecodesign Directive 

2011/65/EU RoHS Directive

Summary of Contents for BHA

Page 1: ...BHASUMEN 005 www bora com Operating and assembly instructions BHAS BHA BHU BORA Basic Hyper glass ceramic cooktop with cooktop extractor exhaust recirculation EN...

Page 2: ...ntents are prohibited unless expressly authorised These operating and installation instructions have been drawn up with the greatest of care But it cannot be ruled out that subsequent technical modifi...

Page 3: ...ooktop extractor with a fireplace which does not depend on room air 23 6 8 Establishing the power connection 28 6 9 Handover to user 29 7 Operation 30 7 1 Switch on off the cooktop and cooking zone 30...

Page 4: ...he proper electrical installation and commissioning Gas specialists The gas connection may only be established by certified engineers They also assume responsibility for proper installation and commis...

Page 5: ...ighted with symbols and signal words Safety and warning information is structured as follows WARNING SYMBOL AND SIGNAL WORD Type and source of the danger Consequences of non compliance X X Measures to...

Page 6: ...h hot cooking surfaces is not possible X X Do not place any objects on the operating panel or the cooktop extractor air inlet nozzle X X Switch off the appliance after use X X Keep pets away from the...

Page 7: ...X X When using recirculation mode ensure a sufficient supply of fresh air e g by opening a window X X Ensure a normal and comfortable room climate humidity of 45 60 e g by opening natural ventilation...

Page 8: ...acted from the chimney or outlet duct into the living area X X Make sure that there is always a sufficient air supply WARNING Risk of burns from hot objects The cooktop and its exposed parts are hot w...

Page 9: ...stainless steel grease filter 2 4 Safety Instructions Installation The appliance must only be installed and assembled by trained specialists who are familiar with and comply with the standard nationa...

Page 10: ...ct stripping of the connection cable to external switching devices results in a risk of electric shock X X Ensure that the stated stripping lengths are adhered to Special safety information for exhaus...

Page 11: ...e power supply cable This may only be done by an authorised member of the After Sales Service team 2 8 Use as intended The appliance cannot be used at altitudes above 2 000 m metres above sea level Th...

Page 12: ...mption Cooking zone 1 210 mm 187 6 Wh kg Cooking zone 2 140 mm 177 5 Wh kg Cooking zone 3 210 mm 219 7 Wh kg Cooking zone 4 140 mm 181 2 Wh kg Total 191 5 Wh kg Extraction system BHA Maximum flow volu...

Page 13: ...3 7 BHU Device dimensions side view 89 100 222 484 596 15 5 647 6 196 Fig 3 4 Device dimensions with cable extension BHA BLAVH1 Device dimensions BHU 380 515 650 120 253 760 476 R 3 275 142 Fig 3 5 B...

Page 14: ...asured electric power input at best efficiency point WBEP 171 2 W Time increase factor f 1 4 Lighting Lighting efficiency LEhood lx W Lighting efficiency class Nominal power of the lighting system WL...

Page 15: ...smoke or exhaust air flue that is not in operation the installation must be checked and approved by a qualified heating engineer Recirculated air mode The air suctioned away by the cooktop is purifie...

Page 16: ...ive timer run down Off Timer off Timer display 0 1 99 Set minutes for short time egg timer or automatic cut off 00 Timer on no time set Tab 5 1 Meaning of displays Touch control The operating panel is...

Page 17: ...inutes 5 3 How the cooking zone works Under the cooking zone is a radiant heating element with a heating tape When the cooking zone is switched on the heating tape generates radiant heat which directl...

Page 18: ...y The filter service display becomes active after the cooktop extractor has operated for 150 hours The activated charcoal filters have reached the end of their service life with recirculation only and...

Page 19: ...ake sure it is complete X X If there are any missing or damaged parts please notify BORA Customer Services immediately X X Do not under any circumstances install parts which are damaged X X Dispose of...

Page 20: ...that it can be removed for maintenance work Q Q To ensure sufficient cooktop ventilation a minimum distance of 15 mm to the bottom edge of the cooktop is to be observed Q Q The drawers and or shelves...

Page 21: ...the height of the rear wall so that the furniture body is closed to the front 6 x 5 Fig 6 10 Cut out and connection bores X X With surface installation attach the included sealing tape 2 on the unders...

Page 22: ...the two outer locks 1 and the middle lock 2 click 2 4 3 1 Fig 6 14 Hooking in the frame of the flexible duct 1 Position shackles 2 Retaining groove on the activated charcoal filter housing 3 Flexible...

Page 23: ...s flow water heaters instantaneous water heaters draw in air from the room in which they are installed and discharge the exhaust fumes to the outside via an exhaust system e g chimney When the cooktop...

Page 24: ...00 mm Fig 6 18 Incorrect exhaust air system installation Fig 6 19 Correct exhaust air system installation X X When running the cooktop extractor in the room in which a fireplace is installed make sure...

Page 25: ...um cross section of the exhaust air ducts must be 176 cm2 This equates to a cylindrical tube with a diameter of 150 mm Q Q The maximum exhaust air duct length is 6 m Q Q Planning information for the i...

Page 26: ...ings 2 2 2 1 Fig 6 30 Engaging the airflow assembly 1 Airflow assembly 2 Openings X X Now move the airflow assembly 1 to the right until it engages fully into the slot of the opening 2 2 1 Fig 6 26 Re...

Page 27: ...Stainless steel grease filter 5 Worktop cut out 6 Exhaust air arc 7 Exhaust air duct 8 Mounting bracket 1 1 1 Fig 6 31 Position lock 1 Shackles for transport and position lock X X Press the two shackl...

Page 28: ...afety and warning information see Safety chapter X X Observe all national and regional laws and regulations as well as the supplementary regulations of the local utility companies INFO The power conne...

Page 29: ...the cable routing to the rear X X Make sure that the cable is not clamped or damaged and cannot touch any hot parts of the cooktop X X Verify that the installation was done correctly X X Switch on th...

Page 30: ...o power level 9 X X If one cooking zone is operated with the P power setting then the operation of the second cooking zone on this side is possible at a maximum of power level 5 X X If power level 5 i...

Page 31: ...ay the set time is displayed and the cooking zone indicator light flashes X X Press until the timer display shows 00 Switching on the automatic pre cook valve X X Press the cooking zone button e g for...

Page 32: ...e is run through Fig 7 2 Fan level sequence 7 1 10 Activating deactivating the child safety lock Activating the child safety lock INFO If a cooking zone indicator alternately shows L and H this means...

Page 33: ...layed or X X press or several times until the fan level indicator 0 is displayed When the fan level indicator displays 0 the cooktop extractor is switched off automatically after a few seconds 7 3 Pay...

Page 34: ...use any aggressive acidic or alkaline cleaning agents 8 2 Maintaining the cooktop X X Do not use the cooktop as a worktop or shelf X X Do not push or pull cookware across the cooktop X X Always lift...

Page 35: ...air guiding housing Greasy deposits and limescale residues from the cooking vapour can accumulate on the surface of the air guiding housing Regular thorough cleaning see Table 7 1 is thus necessary T...

Page 36: ...fan level indicator indicates F filter service display BAKF activated charcoal filters can be pur chased from your specialist You can also contact BORA on its homepage http www bora com X X Make sure...

Page 37: ...the activated charcoal filter housing cover in the centre until the middle lock 3 engages X X Press the activated charcoal filter housing cover on the sides and close the outer locks 1 until they eng...

Page 38: ...the fan level indicator One or more sensor buttons are covered e g due to finger contact or by objects placed on them Clean the control panel or remove objects see Device description chapter ER03 is s...

Page 39: ...ally friendly disposal Disposal of transport packaging INFO The packaging protects the device from damage in transport The packaging materials have been selected from environmental and disposal perspe...

Page 40: ...BORA Expressly not covered by the BORA manufacturer s warranty are Q Q BORA products that were not sold by authorised BORA dealers Q Q Damage caused by non adherence to the operating instructions inc...

Page 41: ...EN 41 Notes www bora com 12 Notes...

Page 42: ...EN 42 Notes www bora com...

Page 43: ......

Page 44: ...derndorf Austria T 43 0 5373 62250 0 F 43 0 5373 62250 90 mail bora com www bora com Europe BORA Holding GmbH Innstra e 1 6342 Niederndorf Austria T 43 0 5373 62250 0 F 43 0 5373 62250 90 mail bora co...

Reviews: