background image

EN

18

Installation

www.bora.com

4.4.4  Special assembly instructions for gas 

cooktop CKG

X

X

Please note the local regulations and connection requirements 

applicable to gas cooktops.

X

X

Before connecting the appliance, check that the appliance 

settings comply with local connection requirements  

(gas type and pressure).

 

i

Minimum requirement for operating gas cooktop CKG: 

System software 03.00 (or higher) 

X

X

If necessary, retrieve the installed software version  

(see operating instructions, Menu chapter, Retrieving the 

software version).

X

X

Update the system software if necessary (see operating 

instructions, Menu chapter, Updating the system software).

 

i

Minimum clearance of 650 mm between the worktop and 

wall unit in the case of gas devices.

 

i

On recirculation systems, a return flow aperture of at 

least 1,000 cm² must be provided for each air cleaning 

unit.

 

i

Ensure sufficient ventilation.

 

i

Taking into account the applicable valid regulations, 

the cooktop must be connected to the gas line with an 

upstream stopcock.

 

i

The gas supply pipe can be connected after the gas 

cooktop has been installed.

 

i

The hose connection must be laid in such a way that it is 

not subject to deformation, buckling or abrasion.

 

i

The stopcock and gas supply pipe connections must be 

accessible.

 

i

It must be possible to inspect the entire length of the 

hose line once installed.

 

i

Only compatible connection pieces are to be used for the 

hose line.

 

i

The pressure regulator must correspond to the set gas 

type and set gas pressure and must meet local and legal 

requirements.

 

i

The gas connection hose line must not come into contact 

with smoke or the flue outlet of an oven.

 

i

The hose line must not come into contact with hot 

surfaces on the cooktop or other devices.

 

i

The gas hose must be inspected every 5 years and 

replaced if necessary. The gas hose must meet the 

requirements of EN14800.

4.4.3  Recirculation when using the cooktop 

extractor as a recirculation system

In the case of recirculation systems there must be a return flow 

aperture in the kitchen units:

X

O

> 500 cm² (per air cleaning box) in combination with cooktops 

CKFI, CKI, CKIW, CKCH, CKCB and CKT

X

O

> 1000 cm² (per air cleaning box) in combination with gas 

cooktop CKG

 

i

If several extractor systems are operated in recirculation 

mode, the return flow aperture for each air cleaning box 

must be calculated correspondingly. Example:  

2 recirculation systems = 2 x (> 500 cm²) or  

2 x (> 1,000 cm²) in the case of gas appliances

For recirculation, the necessary return flow aperture can be 

created using a shortened plinth. A slatted plinth with at least 

the minimum opening cross-section can also be used.

X

X

Ensure that the return flow aperture is large enough.

4

5

1

3

2

Fig. 4.4 

Recirculation design example (kitchen  

c CKA2// air cleaning unit)

[1] 

Cooktop

[2] 

Cooktop extractor CKA2/CKA2AB (recirculation)

[3] 

Air cleaning unit (ULB1, ULB3, ULBF)

[4] 

BORA plinth fan EC (ULS)

[5] 

Recirculation return flow aperture 

 

(Total opening cross section per air cleaning unit ≥500 cm² or 

≥1000 cm² in the case of gas cooktop CKG)

 

i

If the gas flame goes out, is excessively affected by the 

extractor and/or the flame is not as it should be (e.g. 

soot production, flame blowback, etc.), the return flow 

aperture must be enlarged.

Summary of Contents for 40.001.969

Page 1: ...EN BORA Classic 2 0 system installation instructions Cooktop extractor and cooktops C2XIMEN 005 www bora com...

Page 2: ...mbling the extraction system 22 4 8 1 Assembling cooktop extractor CKA2 CKA2AB 22 4 9 Installing the cooktop extractor 23 4 9 1 Fitting and positioning the cooktop extractor 23 4 10 Installing the duc...

Page 3: ...death or serious injury if not respected Caution Indicates a potentially hazardous situation which can cause minor injury or damage to property if not respected Tab 1 1 Meaning of the warning symbols...

Page 4: ...d Appliance components e g pan supports operating controls covers grease filters etc can cause injury if dropped X X Place any appliance components that have been removed in a safe place near the appl...

Page 5: ...nly install the device with the power disconnected X X Connect both sides of the fan to the duct system before commissioning CAUTION Risk of injury from heavy lifting If not handled correctly carrying...

Page 6: ...y and turn off the mains supply X X Ensure there is a good supply of fresh air open doors and windows X X Plug any leaks immediately Special safety instructions for the planning of extractor systems D...

Page 7: ...tops i i The gas connection must only be worked on by reliable trained specialists who are familiar with and comply with the standard national regulations and supplementary regulations of the local ut...

Page 8: ...50 60 Hz Power consumption including external BORA Universal article fans max 550 W Fuse protection internal TR 3 15 A Dimensions width x depth x height 439 x 515 x 190 mm Weight incl accessories pack...

Page 9: ...kW Fuse protection 1 x 16 A Dimensions width x depth x height 327 x 515 x 58 mm Weight incl accessories packaging 7 9 kg Cooktop Power levels 1 9 P Warming levels 3 Front cooking zone zone 1 power set...

Page 10: ...Hz Power consumption 3 68 kW Fuse protection 1 x 16 A Dimensions width x depth x height 327 x 515 x 58 mm Weight incl accessories packaging 7 6 kg Cooktop Power levels 1 9 P Warming levels 3 Front co...

Page 11: ...5 490 450 32 5 Fig 3 13 CKIW device dimensions side view 3 4 CKIW Parameter Value Supply voltage 220 240 V Frequency 50 60 Hz Power consumption 3 0 kW Fuse protection 1 x 16 A Dimensions width x depth...

Page 12: ...er consumption 3 68 kW Fuse protection 1 x 16 A Dimensions width x depth x height 327 x 515 x 75 mm Weight incl accessories packaging 7 2 kg Cooktop Power levels 1 9 P 2 ring additional switching Warm...

Page 13: ...ection 1 x 16 A Dimensions width x depth x height 327 x 515 x 75 mm Weight incl accessories packaging 7 4 kg Cooktop Power levels 1 9 2 ring connection roaster cooking zone connection Warming levels 3...

Page 14: ...0 kW 0 449 m h Cooktop energy consumption G20 20 mbar Category I2H 20 mbar measurement taken without cooktop extractor High power front burner 800 3000 W 63 3 Normal rear burner 550 2000 W 61 3 Total...

Page 15: ...ooktop Temperature control power levels 150 230 C 250 C 1 9 P Warming levels 3 Front cooking zone zone 1 250 x 220 mm 1750 W Rear cooking zone zone 2 250 x 220 mm 1750 W Temperature control range 70 2...

Page 16: ...act switches may be installed that separate the control unit from the power supply phase separation Only the Home In interface is to be used X X Observe all safety and warning information see the Safe...

Page 17: ...ened depending on the installation situation 4 2 Checking the delivery X X Make sure the delivery is complete and check it for damage X X If there are any missing or damaged parts please notify BORA A...

Page 18: ...d must meet local and legal requirements i i The gas connection hose line must not come into contact with smoke or the flue outlet of an oven i i The hose line must not come into contact with hot surf...

Page 19: ...4 3 Cut out dimensions of the appliance combinations in the case of flush installation i i If the gas cooktop is used in a model with two cooktop extractors it is to be installed at the side If instal...

Page 20: ...0 Fig 4 12 Minimum installation dimensions with round silencer USDR50 4 5 2 Surface mounting B 2 R 5 50 50 495 2 600 Fig 4 9 Cut out dimensions for surface mounting 10 10 40 Fig 4 10 Dimension of supp...

Page 21: ...itchen planner Installation option overview i i The installation options shown below can be fitted on the right or left hand side The following airflow options can be implemented with the BORA Classic...

Page 22: ...adapter panel 2 in such a way that the duct connection is facing left or right as required Fig 4 16 Airflow towards the rear right or left Fig 4 17 Straight airflow towards the side right or left 4 8...

Page 23: ...of the worktop X X Saw out the necessary cut outs for the ducting in the rear panel of the floor unit X X Depending on the installation situation adjust the levelling feet on the floor unit as necess...

Page 24: ...ions for the BORA plinth fan X X Connect the plinth fan ULS 9 to the Ecotube shallow round offset transition piece EFRV 8 X X Connect the Ecotube shallow round offset transition piece EFRV 8 to the sh...

Page 25: ...X Use only BORA Universal fans If additional fans are installed at a later date X X When installing additional fans at a later date carry out the initial operation procedure see Initial operation O O...

Page 26: ...y devices e g window contact switches If the switch is open the cooktop extractor is off i i No window contact switches may be installed that interrupt the control unit power supply phase separation O...

Page 27: ...Ensure that the control unit is disconnected from the power supply X X Loosen the screw 4 on the housing cover 1 X X Carefully release all locks 2 with a slotted screw driver X X Remove the housing co...

Page 28: ...connection cables X X Close and secure the control unit cover X X Screw down the lid with the screw provided max 2 Nm X X Make sure that the cable is not damaged or trapped 4 13 Establishing communic...

Page 29: ...e protection Minimum cross section 1 phase connection 1 x 16 A 1 5 mm Tab 4 7 Fuse protection and minimum cross section i i A damaged mains cable must be replaced by another suitable mains cable This...

Page 30: ...op extractor is in use 4 14 3 Additional installation notes for Australia and New Zealand AU NZ i i Observe the requirements on the installation of the appliance pursuant to AS NZS 5601 1 minimum clea...

Page 31: ...automatic circuit breaker X X Secure the main switch automatic circuit breaker against being switched back on without permission X X Make sure the power to the appliance is disconnected 4 14 4 Gas co...

Page 32: ...he gas cooktop is set by default to natural gas G20 20mbar pre assembled i i Special setting for Australia and New Zealand The gas cooktop is set by default to natural gas 1 0 kPa G20 10mbar pre assem...

Page 33: ...her not be displayed at all or will be shown with an error code E also see Operating instructions Troubleshooting chapter X X Switch the system off long press on the power button X X Check the connect...

Page 34: ...ooktop CKG X X Switch the cooking zone on The electronic gas regulator will calibrate itself humming noises and then the gas flame will automatically ignite in the selected cooking zone The gas flame...

Page 35: ...health or the environment if disposed of improperly or incorrectly handled X X Never put your old appliance in domestic waste X X Take the old appliance to a regional collection point for return and...

Page 36: ...his eventuality An updated version can be requested from the BORA Service Team Subject to printing errors and mistakes BORA Vertriebs GmbH Co KG All rights reserved AU NZ BORA APAC Pty Ltd 100 Victori...

Reviews: