EN
29
Installation
www.bora.com
4.13.5 Positioning the control unit
i
The control unit must be placed inside the kitchen unit.
i
Position the control unit inside the kitchen unit in such a
way that it cannot be freely accessed by the user
(e.g. behind the plinth panel).
Permitted positions inside the kitchen unit:
X
O
loose on a false floor
X
O
loose on the shallow duct
X
O
mounted on the kitchen unit
i
When positioning the control unit please observe the
length of the mains cable (1 m).
4.13.6 Connecting to the mains
X
X
Observe all safety and warning information
(see the Safety chapter).
X
X
Observe all national and regional laws and regulations as
well as the supplementary regulations of the local utility
companies.
i
The power connection may only be established by
certified specialists. The specialist also assumes
responsibility for the proper installation and
commissioning.
Special information for CKT:
i
The Classic Tepan stainless steel grill CKT is intended
to be operated on a supply network with an impedance
Zmax at the transfer point (mains connection) of 0.1247
ohms maximum. The user is to ensure that the appliance
is only operated on a mains supply network which meets
this requirement. If necessary, ask the local energy
supply company about the system impedance.
Cooktop power connection
The mains cable to be used (pre-assembled) must be at least
Type H05V2V2-F.
Connection
Fuse protection Minimum cross-section
1-phase connection 1 x 16 A
1.5 mm²
Tab. 4.7
Fuse protection and minimum cross-section
i
A damaged mains cable must be replaced by another
suitable mains cable. This may only be done by an
authorised member of the After Sales Service team.
X
X
Switch off the main switch/automatic circuit breaker before
connecting the cooktop.
X
X
Secure the main switch/automatic circuit breaker against
being switched back on without permission.
X
X
Make sure the power to the appliance is disconnected.
X
X
Only connect the cooktop using a fixed mains connection.
4.13.3 Establishing contact between the
operating unit and control unit
1
Fig. 4.37
Socket for the CAT 5e communication cable on the
operating unit
1
2 3
4
5
6
Fig. 4.38
Control unit connections
[1]
CAT 5e communication cable socket
[2]
Control unit socket for fan 2
[3]
Control unit socket for fan 1
[4]
Mains cable socket for fan 2
[5]
Mains cable socket for fan 1
[6]
Mains cable socket with micro fuse
X
X
Using the CAT 5e communication cable (included in the scope
of delivery) link the connections [1] on the operating unit to
the control unit.
i
The operating unit is controlled by and receives its power
supply via the CAT 5e communication cable.
4.13.4 Connecting fans to the control unit
2
1
Fig. 4.39
Fan connection plug
[1]
Fan mains cable connection plug
[2]
Fan control cable connection plug
X
X
Connect the fan control cable [2] to the control unit.
X
X
Connect the fan mains cable [1] to the control unit.
X
O
When connecting the fan control cable and mains cable it
does not matter if you use socket 1 or 2 on the control unit.