4.16
Sealing the devices
1
Fig. 4.46
Silicone sealant for flush installation
[1]
black, heat-resistant silicone sealant
1
Fig. 4.47
Silicone sealant for surface mounting
[1]
black, heat-resistant silicone sealant
X
X
Once all of the installation work and initial operation is
complete, seal the devices all around with black, heat-
resistant silicone sealant (also between the cooktop extractor
and cooktop) [1].
X
X
Make sure that no silicone sealant gets under the cooktop.
4.17 Handover to user
Once installation is complete:
X
X
Explain the main functions to the user.
X
X
Explain all safety-related aspects of operation and handling to
the user.
X
X
Affix the identification plates provided to the penultimate
page in the operating instructions (see Operating instructions,
Identification plates chapter).
If a CKG gas cooktop is installed:
X
X
also affix the nozzle set nameplate to the inside of the back
cover of the CKG gas cooktop operating instructions.
X
X
Provide the user with the accessories and operating and
installation instructions, which are to be kept in a safe place.
4.15.2 Function test
X
X
Carry out a thorough function test on all devices.
X
X
In the event of error messages, see the “Troubleshooting”
chapter in the operating instructions.
Function test on gas cooktop CKG
X
X
Switch the cooking zone on.
The electronic gas regulator will calibrate itself (humming noises)
and then the gas flame will automatically ignite in the selected
cooking zone.
The gas flame will burn steadily and evenly.
Using the gas cooktop together with the cooktop
extractor for the first time
X
X
Switch the cooktop extractor to the maximum power level.
X
X
Switch all cooking zones to the minimum power level.
The electronic gas regulator will calibrate itself (humming noises)
and then the gas flame will automatically ignite in the selected
cooking zone.
The gas flame will burn steadily and evenly (no reignition). The
gas flame will be slightly affected by the cooktop extractor
(airflow) – this is normal.
i
If the gas flame goes out, is excessively affected by the
extractor and/or the flame is not as it should be (e.g.
soot production, flame blowback, etc.), the characteristic
curve must be increased, as well as the ventilation
in exhaust air mode, if necessary, or the return flow
aperture in recirculation mode.
Faults when using gas cooktop CKG for the first time
When operating for the first time or after a prolonged period
without use or when the liquid gas bottles have been changed,
faults are possible:
X
O
The burner does not ignite.
X
O
There may be air in the gas pipe.
X
X
Repeat the ignition process.
X
O
The burner does not ignite and the cooktop does not react.
X
O
The electronic gas regulator must be recalibrated.
X
X
Using the gas configuration menu,
reset the gas regulator.