background image

 

Contents 

 

             Safety

 

 

The TRM9HC model uses a R290 (Care 40, Propane) refrigerant. Below are some 
safety points which the end user must adopt to mitigate the risk of unsafe conditions 
arising. 

 

Service must only be carried out by a suitably qualified refrigeration engineer. 

 

The unit must be isolated from the electricity supply before removal of the 
covers. 

 

Do not damage/puncture the refrigeration circuit. 

 

This unit is not intended for use in lobbies or locations of egress, such as 
hallways or public corridors. 

 

Ventilation openings must be clear of obstructions. 

 

There must be a gap of at least 100mm between the appliance and a wall or 
other restriction. 

 

Where components are replaced, the new component must be of the same 
type. 

 

Operate the unit within (ambient) operating temperatures; 16

⁰C to 38⁰C. 

 

Introduction 

The TRM9HC is a dry block chiller designed to provide chilled still water by pa

ssing water 

through  a  stainless  steel  water  coil  in  the  “cold  block”. 

The  TRM9HC  in  standard 

configuration is designed as a single product  chiller  with an  option  of two  depending on 
targeted drink temperature.  

 
Important:

 

It is essential that the TRM9HC be turned off during cleaning to prevent 

the cleaning fluid in the product line from freezing. 

 

Section 

Page 

Section 

Page 

Safety, Introduction & Specification 

2-3 

Fault Finding 

Installation & 

Commissioning 

Replacement Parts 

10 

Cleaning 

5-6 

Removal, Transportation 

and Disposal 

11 

Schematics 

7-8 

 

 

Introduction and Specification 

 

Summary of Contents for TRM9HC

Page 1: ...Product Manual TRM9HC Water Cooler Part Number 3B8108 Issue OR ...

Page 2: ... or other restriction Where components are replaced the new component must be of the same type Operate the unit within ambient operating temperatures 16 C to 38 C Introduction The TRM9HC is a dry block chiller designed to provide chilled still water by passing water through a stainless steel water coil in the cold block The TRM9HC in standard configuration is designed as a single product chiller w...

Page 3: ...ssor Cubigel NLY12RAa Dry Weight 27Kg This product contains fluorinated greenhouse gas with a GWP of 3 in an hermetically sealed system Supply 220 240Vac 50Hz Climatic Class N Power Consumption 168W Refrigerant 290a 55g 0 055Kg Introduction and Specification ...

Page 4: ...ispense until all air has been purged from the system 6 Once all air has been purged from the system connect the unit to the electrical supply and turn on After a short delay the compressor and fans will start 7 After approximately 10 minutes the compressor and fan will stop as the chiller has reached its normal operating temperature Note The time taken for the chiller to reach operating temperatu...

Page 5: ...ponent ensuring that the whole area has been covered Finish the clean by exchanging the cleaning agent for warm water remove the soil with a multi purpose disposable cleaning cloth and dry the component with disposable paper towels Food Grade Antibacterial Wipe Remove the dispense components wipe the dispense component with the food grade antibacterial wipe remove all visible soil Replace dispense...

Page 6: ...mmended that the procedure is performed during initial installation and at least every 3 months Prepare the Unit 1 Disconnect the electrical power to the unit and isolate from the water supply 2 Carefully follow the manufacturer s instructions and prepare a solution of proprietary sanitizing fluid Sanitize the Water System 3 Disconnect flexible water inlet tube from the water supply and place the ...

Page 7: ...7 Electrical Schematic ...

Page 8: ...8 Water Schematic ...

Page 9: ...ble Cause Corrective Action No Water Dispensing Frozen block Thermostat capillary not fully inserted into chiller block Thermostat out of calibration or faulty Replace if necessary Warm Drinks Insufficient air flow through the fridge Check supply to cooling fans 220 240v AC If supply present replace fans If supply not present move on to the compressor The supply to the fans and the compressor are ...

Page 10: ...10 Spare Parts 1A6794 Eliwell Controller 3B7692 Fans 1B6430 Power Switch ...

Page 11: ...upright position As with all refrigeration systems irreparable damage can be caused by laying the unit on its side or even transporting upside down Where the unit is transported by a carrier the carton should always be marked in a conspicuous manner the correct upright position in which it must be handled If a unit has been transported incorrectly it should be placed in the correct upright positio...

Page 12: ...12 Booth Dispensers Ltd Moor Park Avenue Blackpool Lancashire FY2 0LZ UK 44 1253 501800 ...

Reviews: