Contents
Safety
The TRM9HC model uses a R290 (Care 40, Propane) refrigerant. Below are some
safety points which the end user must adopt to mitigate the risk of unsafe conditions
arising.
Service must only be carried out by a suitably qualified refrigeration engineer.
The unit must be isolated from the electricity supply before removal of the
covers.
Do not damage/puncture the refrigeration circuit.
This unit is not intended for use in lobbies or locations of egress, such as
hallways or public corridors.
Ventilation openings must be clear of obstructions.
There must be a gap of at least 100mm between the appliance and a wall or
other restriction.
Where components are replaced, the new component must be of the same
type.
Operate the unit within (ambient) operating temperatures; 16
⁰C to 38⁰C.
Introduction
The TRM9HC is a dry block chiller designed to provide chilled still water by pa
ssing water
through a stainless steel water coil in the “cold block”.
The TRM9HC in standard
configuration is designed as a single product chiller with an option of two depending on
targeted drink temperature.
Important:
It is essential that the TRM9HC be turned off during cleaning to prevent
the cleaning fluid in the product line from freezing.
Section
Page
Section
Page
Safety, Introduction & Specification
2-3
Fault Finding
9
Installation &
Commissioning
4
Replacement Parts
10
Cleaning
5-6
Removal, Transportation
and Disposal
11
Schematics
7-8
Introduction and Specification
Summary of Contents for TRM9HC
Page 1: ...Product Manual TRM9HC Water Cooler Part Number 3B8108 Issue OR ...
Page 7: ...7 Electrical Schematic ...
Page 8: ...8 Water Schematic ...
Page 10: ...10 Spare Parts 1A6794 Eliwell Controller 3B7692 Fans 1B6430 Power Switch ...
Page 12: ...12 Booth Dispensers Ltd Moor Park Avenue Blackpool Lancashire FY2 0LZ UK 44 1253 501800 ...