background image

 

1. 

The TRM9HC unit should be located on a firm level surface capable of holding the 
weight, as close to the dispense point as possible, and orientated so that the on/off 
switch and Eliwell control are accessible. Ensure at least 100mm of space is left all-
round the unit to allow adequate airflow for cooling.  

2. 

Connect using John Guest fittings 

to “Product In” on the front of the cooler. 

3. 

Connect using John Guest fittings to “Product Out” on the front of the cooler and feed 
the insulated product line to the dispense tap. 

Note: At this stage do not connect the unit to the electrical supply. 

4. 

Connect the chiller to the water supply and open the mains supply isolation valve. 

5. 

Activate the still water dispense until all air has been purged from the system.  

6. 

Once all air has been purged from the system, connect the unit to the electrical supply 
and turn on. After a short delay the compressor and fans will start.

 

7. 

After approximately 10 minutes, the compressor and fan will stop as the chiller has 
reached its normal operating temperature. 

Note: The time taken for the chiller to 

reach  operating  temperature  will  vary  depending  on  ambient  temperature, 
humidity and the temperature of the incoming water supply. 

8. 

Maintenance:  Wipe occasionally with damp cloth. 

9. 

If compressor or thermostat problems occur the control will shut the compressor off 
and display an error code. This should be quoted when requesting assistance. 

 

Product Connections 

 

 

 

Connection 

Connection Size/Type 

Product In 

1/2

” John Guest Speed Fit 

Chilled Product Out 

1/2

” John Guest Speed Fit 

Installation and Commissioning 

 

Product Out 

Product In 

Summary of Contents for TRM9HC

Page 1: ...Product Manual TRM9HC Water Cooler Part Number 3B8108 Issue OR ...

Page 2: ... or other restriction Where components are replaced the new component must be of the same type Operate the unit within ambient operating temperatures 16 C to 38 C Introduction The TRM9HC is a dry block chiller designed to provide chilled still water by passing water through a stainless steel water coil in the cold block The TRM9HC in standard configuration is designed as a single product chiller w...

Page 3: ...ssor Cubigel NLY12RAa Dry Weight 27Kg This product contains fluorinated greenhouse gas with a GWP of 3 in an hermetically sealed system Supply 220 240Vac 50Hz Climatic Class N Power Consumption 168W Refrigerant 290a 55g 0 055Kg Introduction and Specification ...

Page 4: ...ispense until all air has been purged from the system 6 Once all air has been purged from the system connect the unit to the electrical supply and turn on After a short delay the compressor and fans will start 7 After approximately 10 minutes the compressor and fan will stop as the chiller has reached its normal operating temperature Note The time taken for the chiller to reach operating temperatu...

Page 5: ...ponent ensuring that the whole area has been covered Finish the clean by exchanging the cleaning agent for warm water remove the soil with a multi purpose disposable cleaning cloth and dry the component with disposable paper towels Food Grade Antibacterial Wipe Remove the dispense components wipe the dispense component with the food grade antibacterial wipe remove all visible soil Replace dispense...

Page 6: ...mmended that the procedure is performed during initial installation and at least every 3 months Prepare the Unit 1 Disconnect the electrical power to the unit and isolate from the water supply 2 Carefully follow the manufacturer s instructions and prepare a solution of proprietary sanitizing fluid Sanitize the Water System 3 Disconnect flexible water inlet tube from the water supply and place the ...

Page 7: ...7 Electrical Schematic ...

Page 8: ...8 Water Schematic ...

Page 9: ...ble Cause Corrective Action No Water Dispensing Frozen block Thermostat capillary not fully inserted into chiller block Thermostat out of calibration or faulty Replace if necessary Warm Drinks Insufficient air flow through the fridge Check supply to cooling fans 220 240v AC If supply present replace fans If supply not present move on to the compressor The supply to the fans and the compressor are ...

Page 10: ...10 Spare Parts 1A6794 Eliwell Controller 3B7692 Fans 1B6430 Power Switch ...

Page 11: ...upright position As with all refrigeration systems irreparable damage can be caused by laying the unit on its side or even transporting upside down Where the unit is transported by a carrier the carton should always be marked in a conspicuous manner the correct upright position in which it must be handled If a unit has been transported incorrectly it should be placed in the correct upright positio...

Page 12: ...12 Booth Dispensers Ltd Moor Park Avenue Blackpool Lancashire FY2 0LZ UK 44 1253 501800 ...

Reviews: