background image

Cod. 122591 – Agg. 28.05.2010 

 
 
 

 

 

 

RAPID 10–15–30 

 

 

 

 

 

 

  

 

 
 
 

 

 

ELECTRIC UNVENTED WATER HEATER 

INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE 

 

 

Summary of Contents for RAPID 10

Page 1: ...Cod 122591 Agg 28 05 2010 RAPID 10 15 30 ELECTRIC UNVENTED WATER HEATER INSTRUCTIONS FOR INSTALLATION USE AND MAINTENANCE ...

Page 2: ...ost with low interest rates PRICE MATCH always get the best deals available Boilers Radiators Heating controls Pipes ittings Cylinders Fires Renewable energy Bathroom suites Kitchen sinks taps Showers Wet rooms Towel warmers Bathroom furniture much more H U G E R E D U C T I O N S we have ON THOUSANDS OF ITEMS 0 8 4 4 8 0 0 3 4 6 0 CALL US ON visit our website plumbnation co uk ...

Page 3: ......

Page 4: ...alled as undersink applications and vice versa No type of conversion is possible because the type of heating element and the safety and adjustment thermostat setting do not allow it 3 1 Wall mounting After checking that that wall is strong enough fix 2 hooks of suitable size not supplied to it making sure they a securely anchored Then hang the appliance on the hooks by means of the support bracket...

Page 5: ...from the tap check for any leaks in the various plumbing connections It is advisable to clean the pipes before installation The electrical connection can only be made after this operation 3 5 Electrical connection NB The appliance is arranged for installation with fixed pipe for the electrical connection Make sure the mains voltage matches the value given on the appliance dataplate and that the el...

Page 6: ...o decrease the temperature Refer to the relevant notch located on the thermostat To prevent the formation of legionella an adjustment close to the factory setting towards the notch is advisable 4 3 2 Models with external selector Adjustment is made by turning the knob selector located on the cover see fig 10 Max temperature setting is obtained by turning the selector in the proximity of the wordin...

Page 7: ...n remove the electrical protection cover Fig 7 Ref 9 using a screwdriver and disconnect the electrical wires and indicator lamp from the respective terminals remove the thermostat remove the counterflange using a suitable spanner for M10 nuts and remove it from the housing check the good condition of the anode and replace if necessary removing it together with its support with the aid of pliers th...

Page 8: ...ectly inserted for models with external selector follow the specific assembly instructions Fig 8 9 10 before reconnecting the power fill the appliance see the relevant section and check for any water leaks 6 KEY OF DIAGRAMS AND FIGURES Fig Drg 3 4 and 5 Fig Drg 13 14 15 1 MEMBRANE EXPANSION TANK 2 6 BAR PRESSURE SAFETY VALVE SUPPLIED 3 COLD WATER FEED COCK 4 PRESSURE REDUCER 1 Anode inspection cov...

Page 9: ... definitive solution is to install a water softener A dispenser may not be sufficient Dripping from water safety unit Internal pressure greater than or equal to 0 7 Mpa 7 bar Often due to normal water expansion during heating The system cannot absorb the water expansion in heating To avoid dripping install an expansion tank or connect the safety valve to a drain See the relevant section Dripping f...

Page 10: ...7 SCHEMA ELETTRICO WIRING DIAGRAM Fig 1 SCHÉMA ÉLECTRIQUE SCHALTBILD ESQUEMA ELÉCTRICO Fig 2 ...

Page 11: ...8 Fig 3 Fig 4 RAPID OVERSINK MODELS ...

Page 12: ...9 Fig 5 RAPID UNDERSINK MODELS Fig 6 WALL MOUNTING ...

Page 13: ...APIDI SOPRA E SOTTOLAVELLO RAPID OVERSINK AND UNDERSINK MODELS RAPIDES DESSUS ET DESSOUS ÉVIER SCHNELLWARMWASSERBEREITER FÜR UNTERGESTELLTE INSTALLATION INSTANTÁNEOS ENCIMA Y DEBAJO DEL LAVABO Fig Abb 6 e 7 A B C D E F G 10 261 251 450 228 100 62 189 15 296 285 498 248 100 69 216 30 366 355 568 384 100 89 266 Fig 7 ...

Page 14: ...11 Fig 8 Fig 9 Fig 10 ...

Page 15: ... WITH A MANUFACTURERS WARRANTY OF TWO YEARS FROM DATE OF PURCHASE COVERING MANUFACTURING DEFECTS OR COMPONENT FAILURE DURING THIS PERIOD EXTRAHEAT LTD AT ITS DISCRETION WILL REPAIR OR REPLACE THE UNIT OR ITS COMPONENTS ANY FAILURE DUE TO INSTALLATION CONDITIONS WATER QUALITY OR MIS USE OF THE UNIT WILL NOT BE COVERED UNDER THIS WARRANTY ANY CLAIMS FOR CONSEQUENTIAL COSTS OR LOSS WILL NOT BE CONSID...

Page 16: ......

Page 17: ...EXTRAHEAT LIMITED BELMAYNE HOUSE CLARKEHOUSE ROAD SHEFFIELD S10 2LN TEL 01142 309147 www extraheat co uk sales extraheat co uk ...

Reviews: