18. TANK CLEANING
WARNING! TURN OFF POWER SUPPLY TO THE CABINET BY DISCONNECTING THE POWER
PLUG BEFORE CLEANING.
By tank cleaning, proceed as follows:
1. Place the goods in special refrigerated containers, kept at the same temperature and remove the shelves.
2. Before cleaning the tank the inside temperature must be equal to the ambient temperatur.
3. Leave the doors open and begin the operation of tank washing when the tank temperature is the same as the ambient temperature.
4. Proceed with washing and drying the internal chamber with a cloth using neutral PH detergent and fresh water.
5. Clean the surfaces with a cloth, using neutral PH detergent, rinse and dry.
6.
Clean the height adjusters supporting the levels with a jet of air.
7. Avoid water entering into the appliance lighting units.
8.
Then plug the unit and wait till the appliance reaches the right temperature before filling it again.
Do not use any aggressive or abrasive cleaning agents.
Never use a water hose or a high-pressure jet to clean the cabinet.
WARNING!
Do not use jet of water to clean the cabinet: electrical wiring could be damaged.
WARNING!
Never use mechanical devices or any other means to accelerate the defrosting process,
other than those recommended by the manufacturer.
17. OUTER CLEANING
WARNING! TURN OFF POWER SUPPLY TO THE CABINET BY DISCONNECTING THE POWER
PLUG BEFORE CLEANING.
For a good preservation of the cabinet’s body a periodical cleaning is necessary.
1. EXTERNAL BODY:
When necessary, the external body should be cleaned with a cloth and a neutral soap and water solution.
2. STAINLESS STEEL SURFACES:
Wash with warm water and mild detergent, rinse well and dry with soft cloth. Avoid scouring
pads etc. which will spoil the finish of the stainless steel.
3. SURFACES IN PLASTIC MATERIAL:
Wash with warm water and mild detergent, rinse well and dry with soft cloth; under
no circumstances should alcohol, methylated spirits or solvents be used.
4. GLASS SURFACES:
Only use products specifically designed for glass cleaning; It is not advisable to use ordinary water which
can leave a film of calcium on the surface of the glass.
WARNING!
Do not use jet of water to clean the cabinet: electrical wiring could be damaged.
WARNING!
Never use mechanical devices or any other means to accelerate the defrosting process,
other than those recommended by the manufacturer.
16. MAINTENANCE
WARNING!
Maintenance must be carried out by technical staff trained and enabled for intervention
on the flammable refrigerants.
WARNING! Any work carried out on the appliance by the user strictly requires the power plug being
disconnected from the mains socket.
ATTENTION! Use protective shoes and gloves during maintenance operations.
OPERATION
FREQUENCY
MAINTENANCE
AUTHORISED STAFF
Cleaning the outer surface
Based on use
Ordinary
User
Cleaning the accessible inner parts (do not use tools)
Based on use
Ordinary
User
Checking the power supply, electrical plugs and/or sockets
Six-monthly
Ordinary
User
Seals intactness check
Six-monthly
Ordinary
User
Check the acceptable condition of warning plates
Six-monthly
Ordinary
User
Water collection tank cleaning
Based on use
Ordinary
Technical support
Fridge system tubing intactness check
Six-monthly
Ordinary
Technical support
Inspecting the cables and inner power connections
Six-monthly
Ordinary
Technical support
Replacing the led lights
-
Extraordinary
Technical support
Replacing the power supply cable
-
Extraordinary
Technical support
Control panel replacement (electronic control unit)
-
Extraordinary
Technical support
Any other maintenance operation not planned in the previous points should be carried out by the