7.1.3 Digital Input (PIN4/PIN5 Positive Triggering)
7.1.4 Output (PIN9/PIN10/PIN11/PIN12/PIN13)
7.1.5 Analog Input (PIN6/PIN14)
7.1.5.1 Analog Input Application 1– Detect External Power Voltage
Input range
:
0-6V
Voltage Caculating Formula: input voltage=(AD*6)/1024
0x0377=>887(Decimal)=>(887*6)/1024=5.1972V(Voltage)
0x02FB=>763(Decimal)=>(763*6)/1024=4.4707V(Voltage)