Ac ce ssori e s
User instructions. DGM speed regulator
166
Reset function:
An error can be reset (parameter 1.180) by pressing the reset key
integrated in the foil keypad (foil keypad selection).
Motor-potentiometer function:
The motor-potentiometer function (parameter 2.150) is
implemented using configurable keys I and II integrated in the foil keypad (MOP digital
input). This function can be used to increase or decrease the reference value. The
integrated LEDs display if the minimum and maximum reference values have been
reached.
To activate this function, the reference setpoint indication (parameter 1.130) must be set
on the motor potentiometer!