3.3
Operating behavior
Parameter
Local Remote
412
defines the operating characteristics and enables choosing control via
contacts/control unit and/or the interface.
Parameter
Unit
Setting range
Default settings
No.
Identifier
412
Local Remote
-
LocalRemote table
44 - Ctrl. Cont.+KP,
Dir. Cont.+KP
Operation Modes of Parameter 412
0 - Control via Contacts
Commands Start and Stop as well as definition of
sense of rotation via digital signals.
1 - Control via Statemachine
Commands Start and Stop as well as definition of
sense of rotation via DRIVECOM statemachine of
communication interface.
2 - Control via Remote-Contacts
Commands Start and Stop as well as definition of
sense of rotation via logic signals through the commu-
nication protocol
3 - Ctrl. KP, direction Contacts
Commands Start and Stop from the control unit, defi-
nition of sense of rotation via digital signals.
4 - Ctrl. KP+Cont., direction Cont.
Commands Start and Stop from the control unit or via
digital signals, definition of sense of rotation only via
digital signals.
5 - Ctrl. 3-Wire, direction Cont.
3-wire; control of sense of rotation and the signal
Start 3-wire ctrl.
87
via digital signals.
13 - Control via KP, Direction KP
Commands Start and Stop as well as definition of
sense of rotation via control unit.
14 - Control KP+Cont., Direction KP
Commands Start and Stop via the control unit or digi-
tal signals, definition of sense of rotation only via con-
trol unit.
20 - Control Contacts, Clockw.
Commands Start and Stop via digital signals. Fixed
definition of sense of rotation: clockwise only.
23 - Control Keypad, Clockw.
Commands Start and Stop via control unit. Fixed defi-
nition of sense of rotation: clockwise only.
24 - Control Cont. + KP, Clockw.
Commands Start and Stop via control unit or digital
signals. Fixed definition of sense of rotation: clockwise
only.
30 - Control Contacts, Anticl.
Commands Start and Stop via digital signals. Fixed
definition of sense of rotation, anticlockwise rotation
only.
33 - Control Keypad, Anticl.
Commands Start and Stop via control unit. Fixed defi-
nition of sense of rotation, anticlockwise rotation only.
34 - Control Cont. + KP, Anticl.
Commands Start and Stop via control unit or digital
signals. Fixed definition of sense of rotation, anti-
clockwise rotation only.
43 - Ctrl. Cont.+KP, Dir. Cont.+KP
Commands Start and Stop via control unit, Definition
of sense of rotation via control unit or digital signals.
44 - Ctrl. Cont.+KP, Dir. Cont.+KP
Commands Start and Stop as well as definition of
sense of rotation via control unit or via digital signals.
46 - Ctrl. 3-Wire+KP, Dir. Cont.+KP
3-wire and control unit. Control of sense of rotation
and signal
Start 3-Wire Ctrl
87
via digital signals or
control unit.
11/13
ACU
Winding Drive
19
3.4
Control inputs and outputs
NOTE
Switch off power supply before connecting or disconnecting the control inputs and outputs. Other-
wise, components may be damaged.
•
The unit may only be connected with the power supply switched off.
•
Verify safe isolation from power supply.
3.4.1
Control terminals
The wiring diagram describes the default assignment of control terminals and functions. According to
the requirements of the application, other functions can be assigned to the control terminals.
+10 V / 4
MFI
GND 10
6
X210
+20 V / 180
24
S7IN
S4IN
X210
5
6
7
1
2
3
S3OU
X1
A
D
5 S3IN
4 S2IN
2
S1IN
7 S5IN
3
1
1 S6IN
GND 20
2
4 MFO
S1OU
3
+
-
L L
L
X
V W
U
Rb
X
+
-
Rb
I
U,
G
20
ACU
Winding Drive
11/13