Burner will not
light using a
match
No gas flow
Check if gas cylinder is empty. If yes,
replace.
Regulator is not fully
connected to the tank
Check LP tank connection.
Gas flow is obstructed
Check hose for bends or kinks
Spider webs or insect nest in
the venturi (end of burner
tube)
Clean the venturi
Burner ports are clogged
Insert an opened paperclip into each of
the burner ports to clean them. Ensure
the fire table is off and all parts are
cooled before attempting to clean the
burner ports
Fire table emits
a lot of black
smoke when lit
Flame is obstructed at burner
ports
Make sure all the gas burner ports are
free of any lava rocks or debris to allow
the gas to flow freely.
Regulator hose is pinched
Check the regulator hose for bends or
kinks
Sudden drop in
gas flow
No gas flow
Check if gas cylinder is empty. If yes,
replace.
Excess flow safety valve has
been activated
Turn the control knob to "OFF". Close the
LP tank valve and disconnect the
regulator from the tank. Turn the control
knob to "HIGH". Wait 1 minute. Turn the
control knob to "OFF". Reconnect
regulator to LP tank. Open tank valve
slowly. Light fire table as indicated in "To
Light" section.
Flame blow out
High or gusting winds
Increase flame to "HIGH"
No gas flow
Check if gas cylinder is empty. If yes,
replace.
Excess flow safety valve has
been activated
See "Sudden drop in gas flow" above
Irregular flame
pattern or flame
does not come
out of the entire
length of the
burner
Burner ports are clogged
See "Burner will not light using a match"
above.