Service Training
BW 156/177 D-3/PD-3
- G 19 -
BW 178/179 D-3/PD-3
Switching the vibration on
Current flows from potential K11 via fuse (F03:05) to toggle relay (K04:05).
When pressing the push button (S13:05) the toggle relay will switch and the contact of toggle relay
(K04:05) will close.
Current flows to the selector switch for high / low amplitude (S35:29).
Depending on the switch position current flows to the solenoid valve (Y07:29) for high amplitude or
(Y08:34) for low amplitude. The selected vibration will start.