Service Training
BW 156/177 D-3/PD-3
- F 4 -
BW 178/179 D-3/PD-3
Outer gear pumps are fitted with gap seals. In dependence on the operating pressure there will be
losses from the pressure side to the suction side. An axial pressure field presses the bearing plate on
the cover side against the front face of the gears, making sure that only a very little quantity of oil will
leak from the pressure side to the suction side when the pressure increases.
The pressure field is always under the actual system pressure.