Service Training
Trouble shooting single drum rollers generation 3
ETr 2
No vibration (travel system OK)
Check vibration
Check coupling on
vibration motor
Vibrationspumpe
OK ?
Charge pressure OK
Start pressure too low
Charge pr. / start
pressure too low
Replace / repair the
vibration pump
OK ?
no
yes
Check flushing valve on
vibration motor,
Treplace the
flushing valve
Replace / repair the
vibration motor
OK ?
no
yes
Charge pressure OK
Start pressure zero
Check magnetic
coil of vibration
Voltage /
current OK ?
no
yes
Perform trouble
shooting in electric
system
Check the solenoid
valve, replace if
necessary