![Bomag BW 100 ADM-2 Operating Instructions, Maintenance Instructions Download Page 75](http://html1.mh-extra.com/html/bomag/bw-100-adm-2/bw-100-adm-2_operating-instructions-maintenance-instructions_2785491075.webp)
Every 250 operating hours
BOMAG
75
BW 80 AD-2 Fam.
Fig. 107
l
Blow the coolant radiator (Fig. 107) out from
the air intake side.
Hydraulic oil cooler
Fig. 108
l
Blow the hydraulic oil cooler (Fig. 108) out
from the air discharge side first.
Fig. 109
l
Blow the hydraulic oil cooler (Fig. 109) out
from the air intake side.
Cleaning with cold cleansing agent
!
Caution
Protect electrical equipment such as genera-
tor, regulator and starter against the direct wa-
ter jet.
l
Spray the engine with a suitable cleansing
agent, e.g. cold cleansing agent and wash it
off with a strong water jet after a sufficient
soaking time.
l
Run the engine warm for a short time to avoid
corrosion.
l
Reassemble the blower grid.
Summary of Contents for BW 100 ADM-2
Page 2: ......
Page 7: ...BOMAG 7 BW 80 AD 2 Fam 1 Technical Data...
Page 15: ...BOMAG 15 BW 80 AD 2 Fam 2 Safety regulations...
Page 22: ...Safety regulations BOMAG 22 BW 80 AD 2 Fam...
Page 23: ...BOMAG 23 BW 80 AD 2 Fam 3 Indicators and Controls...
Page 24: ...Indicators and Controls BOMAG 24 BW 80 AD 2 Fam Fig 7...
Page 25: ...Indicators and Controls BOMAG 25 BW 80 AD 2 Fam Fig 8...
Page 35: ...BOMAG 35 BW 80 AD 2 Fam 4 Operation...
Page 53: ...BOMAG 53 BW 80 AD 2 Fam 5 Maintenance...
Page 79: ...Every 500 operating hours BOMAG 79 BW 80 AD 2 Fam...
Page 90: ...As required BOMAG 90 BW 80 AD 2 Fam...
Page 91: ...BOMAG 91 BW 80 AD 2 Fam 6 Trouble shooting...
Page 95: ......
Page 96: ......