![Bomag BW 100 ADM-2 Operating Instructions, Maintenance Instructions Download Page 71](http://html1.mh-extra.com/html/bomag/bw-100-adm-2/bw-100-adm-2_operating-instructions-maintenance-instructions_2785491071.webp)
Every 250 operating hours
BOMAG
71
BW 80 AD-2 Fam.
5.19 Checking the condition, ten-
sion of the V-belt, changing
the V-belt
!
Danger
Danger of accident!
This work must only be performed with the en-
gine shut down.
Checking the V-belt
Fig. 98
l
Examine the entire circumference of the V-belt
(Fig. 98) for damage and cracks. Replace
damaged or cracked V-belts.
l
Apply thumb pressure to check whether the V-
belt can be depressed for more than 7 to 9 mm
between the V-belt pulleys, if necessary reten-
sion.
Tensioning the V-belt
Fig. 99
l
Slacken the fastening screws 1 and 2 (Fig.
99).
l
Press the generator towards the outside until
the correct tension of the V-belt is reached.
l
Tighten all fastening screws and check the V-
belt tension again.
Changing the V-belt
i
Note
Remove the guard from the blower.
Fig. 100
l
Slacken the fastening screws 1 and 2 (Fig.
100).
l
Push the generator completely towards the
engine..
l
Take the old V-belt off.
Summary of Contents for BW 100 ADM-2
Page 2: ......
Page 7: ...BOMAG 7 BW 80 AD 2 Fam 1 Technical Data...
Page 15: ...BOMAG 15 BW 80 AD 2 Fam 2 Safety regulations...
Page 22: ...Safety regulations BOMAG 22 BW 80 AD 2 Fam...
Page 23: ...BOMAG 23 BW 80 AD 2 Fam 3 Indicators and Controls...
Page 24: ...Indicators and Controls BOMAG 24 BW 80 AD 2 Fam Fig 7...
Page 25: ...Indicators and Controls BOMAG 25 BW 80 AD 2 Fam Fig 8...
Page 35: ...BOMAG 35 BW 80 AD 2 Fam 4 Operation...
Page 53: ...BOMAG 53 BW 80 AD 2 Fam 5 Maintenance...
Page 79: ...Every 500 operating hours BOMAG 79 BW 80 AD 2 Fam...
Page 90: ...As required BOMAG 90 BW 80 AD 2 Fam...
Page 91: ...BOMAG 91 BW 80 AD 2 Fam 6 Trouble shooting...
Page 95: ......
Page 96: ......