Figure 2: Overall and Mounting Dimensions
The line of sight between a Receiver and a Keyfob should be free of obstacles.
Inspect the Receiver being placed at selected point detects the signals from all possible user locations.
In order to eliminate deadzones or to increase the operating range it can be possible to locate several
Receivers at various locations, the same Keyfobs being to be registered by each of them. In such a case
Receiver relay outputs can be connected either to the same or to diverse executive devices.
A Receiver mounting procedure is as follows.
1. Select the suitable location keeping in mind all recommendations mentioned above.
2. Take off the Receiver lid.
3. Firmly fix the Receiver base with supplied screws and dowels.
4. Wire the corresponding Receiver terminals to a power supply and an executive device in agreement
with required electrical scheme. Some typical application examples are specified below.
5. If necessary connect the Receiver tamper terminals to an available tamper alarm zone. The Receiver
tamper is brought into a scheme along with EOL resistor in series. The value of EOL resistor is
strongly dependent on specified connecting scheme and the equipment the tamper to be connected
to, so, this subject is beyond the scope of this manual.
6. Replace the Receiver lid.
7. Power up the Receiver and the executive device.
RECEIVER OPERATING MODES
A short pressing on the large Keyfob button activates the relay, while a short pressing on the small one
close the relay operation. The Keyfob light indicator lights up when a button is pressed (that is, the relay is
activated).
The relay can operate by four different ways (or modes) depending on the executive device required
behavior. The minimal relay actuating time shall not be less than 2 seconds irrespective of operating mode.
Mode #1
: The relay is actuated by a large button pressing and remains on until the small Keyfob button
has not been pressed.
Mode #2
: The relay is actuated by pressing on both large and small Keyfob buttons and remains on
until they have been released.
Mode #3
: The relay is actuated by pressing on large Keyfob button and remains on until it has been
released.
Mode #4
: The relay is actuated by a large button long pressing (more than 3 seconds) and remains on
until the small Keyfob button has not been pressed.