TYPICAL APPLICATION 

How to Use the Efir-K as a Panic Alarm System 

1. Make your election of a required Receiver operating mode and program it as explained above. 
2. Program the needful number of Keyfobs to be in use. 
3. Attach the Receiver at a suitable location where all programmed Keyfobs are operating. Do not place 

the Receiver behind metal blinds, near large metal objects, power lines, air conditioners and sources 
of the electromagnetic, thermal and RF fields. 

4. Include the Receiver into available security system connecting switch-over relay dry contacts to the 

Security Station communication line. The Receiver wiring diagram for such an application is shown 
in Figure 3. 

5. Connect the Receiver to a usable power supply. 
Such a system operates as follows. 
As needing help any security system owner sends out an encoding panic signal by means of 

corresponding Keyfob button pressing. 

The Receiver detects the signal and decrypts it. If the signal is authentic Receiver opens the relay dry 

contacts connected to the communication line. As a result Security Station alarm is activated signaling alarm 
conditions having occurred. 

 

Figure 3: Using the Efir-K for Panic Signal Transmitting

 

…………

Keyfob 1 

Keyfob 2 

Keyfob 15 

Receiver

Signal is transmitted to a Security Station

Summary of Contents for EFIR-K

Page 1: ...le barriers or for notification appliances Remote relay control of diverse devices Ensure human safety by means of panic signal transmitting to the Alarm Receiving Center in case of intruder attack Provide a selected remote access FEATURES Strong encrypted RF transmission Remote control by up to 15 Keyfobs Lost Keyfob disabling LED indicating of relay actuation and learning mode entering Choosing ...

Page 2: ...ver transmitter position Large building constructions and metal objects power lines vehicles as well as humans can disturb RF propagation Landscape details and surrounding vegetation can also attenuate the signal In order to improve range of performance attach the Receiver upright away from strong thermal sources air conditioners direct sunlight places likely to cause water drops within the Receiv...

Page 3: ...g with EOL resistor in series The value of EOL resistor is strongly dependent on specified connecting scheme and the equipment the tamper to be connected to so this subject is beyond the scope of this manual 6 Replace the Receiver lid 7 Power up the Receiver and the executive device RECEIVER OPERATING MODES A short pressing on the large Keyfob button activates the relay while a short pressing on t...

Page 4: ...ution Holding the LEARN button for more than 8 seconds will erase the Receiver memory so that data about all Keyfobs programmed before will be lost 5 Shortly press large or small Keyfob button and ensure the Receiver LED goes off If the LED has no gone off then the RF relationship between Receiver and Keyfob is not created DCaution If the programming Keyfob button is not pressed within 30 second i...

Page 5: ...tch over relay dry contacts to the Security Station communication line The Receiver wiring diagram for such an application is shown in Figure 3 5 Connect the Receiver to a usable power supply Such a system operates as follows As needing help any security system owner sends out an encoding panic signal by means of corresponding Keyfob button pressing The Receiver detects the signal and decrypts it ...

Page 6: ...ields 4 Wire the Receiver to your SIGNAL equipment according with the scheme in Figure 4 and directions from Table 1 Such a system operates as follows Being coming out of premises an owner closes the door and presses on the large Keyfob button An encoded control signal is sent out at once The signal is detected and decoded by Receiver In case of authorization having been successful the Receiver re...

Page 7: ...set to ARMED position that is has to be pushed Solder to the contacts 1 and 2 of S3 switch 1 NO opened ХТ2 3 12V 12 2 СОМ common ХТ2 12V 11 2 12V ХТ1 SIGNAL VK2 ХТ2 3 ХТ2 12V 12 4 12V ХТ2 Armed disarmed 11 2 СОМ common ХТ3 Armed disarmed 12 3 NС closed ХТ2 12V 11 2 12V XT1 SIGNAL VK 4P ХТ2 12V 12 4 12V ХТ2 Crypto Device 1 NO opened ХТ5 Crypto Device 2 СОМ common ХТ2 12V 9 2 12V XT1 SIGNAL VK4 iss ...

Page 8: ...n encrypted executive signal The Receiver detects the signal and decodes it If the signal is authorized the switch over dry contacts are opened following by the lock opening In such a process the Receiver LED shall light by red After having gone from the object the owner closes the door and releases the large Key button The Receiver LED shall go out The lock switches on blocking the door Coming ba...

Page 9: ...ls and workmanship for 12 months since putting the Efir K into operation but no more then 18 months since production under normal use and service Sending off the Efir K to the manufacturer for repairing accompany those with a damage certificate describing the defect Send your complaints to the manufacturer at the following address ZAO NVP BOLID 4 Pionerskaya street Korolyov Moscow Region Russia 14...

Page 10: ... Set Product Designation Serial Number Produced tested by quality control department in compliance with state standards and specifications packed by NVP BOLID Company and qualified as deliverable Q C STAMP _____________________ ____________________________ Name Date ...