background image

5.3.1 Examples of DIP Switch Settings

1

O
N

Example 1: one LED signal 

(uses connections S1, B1, B2)

- operational mode 1 – one signal, braking in one direction

- signal has LEDs, the voltage of the red LED is connected to S1.
- braking starts in the first section (B1)

2

3

Variant of example 1: If braking shall start at the second section (B2), then switch 2 is Off.

1

O
N

Example 2: one signal with internal contact 

(uses connections S1, B1, B2)

- operational mode 1 – one signal, braking in one direction

- signal has an internal switch, a switched voltage is connected to S1.
- braking starts in the first section (B1)

2

3

Variant of example 2: If braking shall start at the second section (B2), then switch 2 is Off.

1

O
N

Example 3: two LED signals

 (uses connections S1, S3; B2, B1, B3)

- operational mode 2 – two signals, braking in two directions

- signals have LEDs, the voltage of the red LED is connected to S1 or S3 resp.
- braking only in the last section (B2 or B3 resp.)

2

3

Annotation to example 3: Instead of three track section in sequence B2–B1–B3, also the variant 
with two sections B2–B3 can be used.

1

O

N

Example 4: two signal with internal contacts

(uses connections S1, S3, B2, B1, B3)

- operational mode 2 – two signals, braking in two directions
- signals have an internal switch, a switched voltage is connected to S1 or S3.

- braking only in the last section (B2 or B3 resp.)

2

3

Annotation to example 4: Instead of three track section in sequence B2–B1–B3, also the variant 

with two sections B2–B3 can be used.

5.4 Connections

All external connections of the brake module are labelled on the board and explained in the table 
below:

Label

Function

0

digital track voltage
center stud track: B is the red wire to the center studs, 0 is the brown wire to the rails 

ground.

two-rail track: B is the wire to rail on the right hand side (only this right rail is divided 

into track sections), 0 is the wire to the continuous rail on the left hand side. Note: 
the color code or polarity of the electrical track connection is irrelevant, essential is 

right and left rail as seen when approaching the signal.

B

bogobit Bremsmodul Oneway · 2011-12-29

page 6 / 11

Summary of Contents for Bremsmodul Oneway

Page 1: ...Bogobit Bremsmodul Oneway Manual bogobit Bremsmodul Oneway 2011 12 29 page 1 11...

Page 2: ...red by disregarding these operating instructions the warranty claim is void Liability for any and all consequential damage is excluded We do not assume any liability for damage to property or personal...

Page 3: ...t ensure sufficient air circulation around the device to prevent heat build up and overheating This especially applies when installing the board in a hous ing When mounting the product keep sufficient...

Page 4: ...on Oneway Station is the full featured version On the Oneway Simplex some electronic components are left out as this version only supports one signal signal input and two instead of three track sectio...

Page 5: ...perational Mode DIP Switches The module has three DIP switches These configure the operational behaviour In position Off the switch lever is in the left position near the number In position On the swi...

Page 6: ...example 3 Instead of three track section in sequence B2 B1 B3 also the variant with two sections B2 B3 can be used 1 O N Example 4 two signal with internal contacts uses connections S1 S3 B2 B1 B3 op...

Page 7: ...f the center stud rail With two rail track the isolation must be made to the right rail of the track only The right rail of the normal track outside any brake section is connected to B The individual...

Page 8: ...often called transition segment as required with many other commercial brake modules The bogobit Bremsmodul does not require this Furthermore there is no such segment often called stop segment as req...

Page 9: ...rack segment is 2 A The max sum of all track segment currents is 3 A The maximum relay switching capacity is 2 A current and 30 V DC or AC voltage 7 2 Signal Input Control Voltage The threshold of a c...

Page 10: ...t 8 2 Hazardous Substances Disposal The product if manufactured by Bogobit complies with the Directive 2002 95 EC on the restriction of the use of certain hazardous substances in electrical and elec t...

Page 11: ...ce 1 Wiring schemes German Anschlussbeispiele Bogobit Bremsmodul Oneway see http bogobit de bremsmodul oneway chapter Weiterf hrende Informationen 2 Website on recommended decoder settings http bogobi...