Bogen Communications
50 Spring Street
Ramsey, NJ 07446
201.934.8500 P.
201.934.9832 F.
www.bogen.com
Technician Level Programming
Configuring the Zone Durations from the LCD Display
Each zone (relay) has two configurable durations that can be used during the programming of events. The default durations are three
and five seconds.
1) Type in 6063 at the main screen to enter the technician level menu mode.
2) Press the NO/CANCEL button until the screen shows “Set Zone Durations?” as shown in Fig 3.9.
3) Press the YES/ENTER button.
4) Using the
↑
and
↓
buttons, scroll through each zone number and duration until the desired option is selected as shown in Fig 3.10.
5) Press the YES/ENTER button.
6) Using the keypad, type in the new duration for the selected zone between 0001 - 9999 seconds as shown in Fig 3.11.
7) Press the YES/ENTER button to confirm the selection.
8) Repeat steps 4 - 7 for additional duration changes.
9) To exit and return to the main screen, continue to press the NO/CANCEL button until the main screen appears.
Fig 3.9
Fig 3.10
Fig 3.11