Before installation
Packaging Removal & Unit Placement
Before installation check the extraction unit for damage.
All packaging must be removed before the unit is connected
to the power supply.
Please read all instructions in this manual before using
this extractor.
1. Move the unit to the location where it is going to be
installed and remove the outer packaging.
This unit
should be installed in a well-ventilated area.
2. Open the front door.
Check the filters are located in their correct position
before closing the door and securing the door latches.
Note: The door will not close fully if the Combined filter
has not been secured in place using the internal lever.
(As detailed below)
Ensure that 500 mm space is available around any vented
panels on the extractor to ensure adequate airflow.
Caution
Due to the weight of the extractor suitable lifting
equipment should be used and with regard to
appropriate safety precautions. (See Appendix for
product weight details)
Caution
Under no circumstances should the exhaust
outlet/s be covered as this will restrict the airflow
and cause overheating.
Caution
Do not block or cover the cooling vents on the unit,
as this severely restricts airflow and may cause
damage to the unit.
The FumeCab 700 features a hinged transparent Perspex
panel on the front of the unit. This allows for more room to
place larger work pieces inside the unit when working, while
not restricting the user’s vision.
3
01