afety Instructions

 

 

 
 
 

 

 
Warning and Information labels 

The following listing details labels used on your FumeCab 
700 unit. 
 

Goggles, Gloves & Mask Label 

 
 
 

 

Location: Front face of both filters 
Meaning: Goggles, Gloves and Masks should be worn while 
handling used filters. 
 

Do Not Cover Label

 

 
 
 
 

Location: Rear motor cooling panels and rear left corner of 
unit 
Meaning: Do not cover any louvers or holes adjacent to the 
label. 
 

Electrical Danger 

 
 
 

Location: Upper control panel. 
Meaning: Removal of panels with this label attached will 
allow access to potentially live components. 
 

Warning Label 

 

Location: Door panel, Perspex door 
Meaning: Power should be isolated before the panel with 
this label attached is opened/ removed. 
 
 
 

 

 
Serial Number Label 

 

 

 
 
 
Location: Top left corner of back panel. 
Meaning: This label contains a variety of information about 
the extraction unit, including.   
 

 

Company name, Address & Contact number 

 

Extractor model 

 

Unit serial number 

 

Operating voltage range 

 

Maximum current load 

 

Operating frequency 

 

Year of Manufacture 

 

Relevant approval markings/ logos 
 

PLEASE NOTE: 

If the equipment is used in a manner not 

specified by the manufacturer, the protection provided by 
the equipment maybe compromised. 

Fire Risk Warning 

In the very rare event that a burning ember or spark is 
drawn into the fume extraction unit, it may be possible that 
the filters will ignite. 

Whilst any resultant fire would typically be retained within 
the fume extraction unit, the damage to the extractor 

could

 

be significant. It is therefore essential to minimise the 
possibility of this occurring by undertaking an appropriate 
Risk assessment to determine:- 

a). Whether additional fire protection equipment should be 
installed.  

b). Appropriate maintenance procedures to prevent the risk 
of build-up of debris which could potentially combust. 

This unit should not be used on processes where sparks 
could occur, with explosive dusts and gases, or with 
particulates which can be pyrophoric (can spontaneously 
ignite), without implementation of additional precautions 

It is essential that nozzles or other extraction/ fume capture 
devices and hoses/pipework are cleaned regularly to prevent 
the build-up of potentially ignitable debris

02 

 

 

02 

Summary of Contents for FumeCAB 700

Page 1: ...FumeCAB 700 115V ...

Page 2: ...1 Overview of your extraction system front Overview of your extraction system back Overview of Control Panel Important safety notes Safety labels Unpacking and unit placement Unit Information Connecting to Mains Turning extractor On changing display units Cleaning the unit Pre filter replacement Combined filter replacement Consumable spares Filter disposal FumeCab 700 Specifications ...

Page 3: ...Overview 1 01 Company Branding Control Panel Filter Door Panel Hinged Perspex enclosure panel Door Latch Combined Filter Filter Release Handle Pre Filter Air Inlet Mains Isolation Switch ...

Page 4: ...Overview 1 02 Motor Cooling Mains Inlet Inlet for Tools Equipment Cables Air outlet ...

Page 5: ...Overview 1 03 Main Isolation Switch Lighting Switch Filter Change Indicator Company Branding ...

Page 6: ...oving the pump motor access panel 2 Use only as described in this manual 3 Connect the system to a properly grounded outlet Dangers to eyes breathing and skin Once used the filters within the FumeCab 700 system may contain a mixture of particulates some of which may be sub micron size When the used filters are moved it may agitate some of this particulate which could get into the breathing zone an...

Page 7: ...f Manufacture Relevant approval markings logos PLEASE NOTE If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment maybe compromised Fire Risk Warning In the very rare event that a burning ember or spark is drawn into the fume extraction unit it may be possible that the filters will ignite Whilst any resultant fire would typically be retained...

Page 8: ...been secured in place using the internal lever As detailed below Ensure that 500 mm space is available around any vented panels on the extractor to ensure adequate airflow Caution Due to the weight of the extractor suitable lifting equipment should be used and with regard to appropriate safety precautions See Appendix for product weight details Caution Under no circumstances should the exhaust out...

Page 9: ...ns The supply cord should only be replaced by a BOFA engineer as an electrical safety test may be required after replacement The extraction unit MUST be connected to a properly earthed outlet Connect the power cable to an isolated electrical supply The mains socket should be installed near the extractor it should be easily accessible and able to be switched On Off The cable run should be arranged ...

Page 10: ... switched to the On position the top side of the switch should be depressed to power the unit Please Note To ensure efficient airflow the FumeCab must be used with the clear panel in the down position The extractor and all pipe work must be fully installed and connected before the airflow is set 5 01 ...

Page 11: ...vent build up of dust and overheating of the unit Replacing Filters The FumeCab 700 system will alert the user when its filters need replacing when the red filter change indicator light on the control panel glows Fire Risk Warning In the very rare event that a burning ember or spark is drawn into the fume extraction unit it may be possible that the filters will ignite Whilst any resultant fire wou...

Page 12: ...d filter change indicator located on the control panel glows To remove and replace the combined filter follow the procedure detailed below 1 Isolate the electrical supply to the extractor 2 Undo the catch on the front of the unit and open the filter door 3 Rotate the lever below the filter through 180o to lower the combined filter 4 Using the handle on the front of the filter pull it out of the un...

Page 13: ...filter Date Engineer Date Engineer Filter disposal The Pre and Combined filters are manufactured from non toxic materials Filters are not re usable cleaning used filters is not recommended The method of disposal of the used filters depends on the material deposited on them For your guidance Deposit EWC Listing Comment Non Hazardous 15 02 03 Can be disposed of as non hazardous waste Hazardous 15 02...

Page 14: ...ing speed Size Metric mm Imperial inches Height 780 30 7 Depth 490 19 3 Width 690 27 1 Filters Filter Type Surface area Efficiency Pre filter 1 68 m2 99 0 3micron Combined filter 3 0m2 99 997 0 3micron Combined Filter Gas section Filter Type Carbon type Amount Combined filter Gas Activated carbon 17kgs Environmental operating range Temperature 5o C to 40o C Humidity Max 80 RH up to 31o C Max 50 RH...

Page 15: ... Information BOFA Headquarters 21 22 Balena Close Creekmoor industrial Estate Poole Dorset BH17 7DX UK Phone 44 0 1202 699444 BOFA Americas 303 S Madison Street Staunton Illnois 62088 USA Phone 001 618 205 5007 ...

Reviews: