background image

 

 

 

 
 

 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

 
 
 
 
 
 
 

 

 
 
 
 

 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 

USER MANUAL 

 

DWX-52DCi 

 

V3 Dec 18 

 

Summary of Contents for DWX-52DCi

Page 1: ...USER MANUAL DWX 52DCi V3 Dec 18 ...

Page 2: ... 02 Fume capture Guidelines Connecting to power supply 03 Optional added features 4 01 Turning extractor On setting the airflow 5 01 02 Important safety notes Safety labels 2 01 02 Cleaning the unit Pre filter replacement HEPA filter replacement 6 01 Fault indication Error codes 8 01 DWX 52DCi Specifications 9 01 Fault Indication 7 ...

Page 3: ...Overview 01 1 On Off switch Speed control filter blocked light Override Switch Door Latch Castors Door Hinge Storage compartment Pre filter bag HEPA filter ...

Page 4: ...Overview 02 1 Compressed air outlet Exhaust box outlet Castors Air inlet Mains Power inlet Interface connection ...

Page 5: ...ons for work on live components are always observed Important To reduce the risk of fire electric shock or injury 1 Always isolate the system from the mains power supply before removing the pump motor access panel 2 Use only as described in this manual 3 Connect the system to a properly grounded outlet Dangers to eyes breathing and skin Once used the filters within the system may contain a mixture...

Page 6: ...ns a variety of information about the extraction unit including Company name Address Phone number Extractor model Unit serial number Operating voltage range Maximum current load Operating frequency Relevant approval markings logos PLEASE NOTE If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment maybe compromised Fire Risk Warning In the ve...

Page 7: ... regard to appropriate safety precautions See Appendix for product weight details Caution Do not block or cover the cooling vents on the unit as this severely restricts airflow and may cause damage to the unit Caution Under no circumstances should the exhaust outlet s be covered as this will restrict the airflow and cause overheating 2 Check the filter is located in the correct position before clo...

Page 8: ...e to hazardous substances in order to prevent ill health The use of a suitable extraction system will enable you to conform to the Health and Safety regulations and protect the health employees and others This unit has been designed to remove and filter fume containing potentially hazardous particulate generated during manufacturing processes Such hazardous substances are captured within the filtr...

Page 9: ...nit was ordered with any optional extras please read section 4 03 before the power connection is made as additional connections may be required before power is connected to the extractor The internal compressor is a voltage specific component that MUST be set correctly before any mains voltage is applied to the extractor The voltage selector switch can be found on the mounting base of the compress...

Page 10: ...w when the DC voltage is removed the motor will slow down and come to a stop The extractor will need to be turned on See section 5 for turning the extractor on in order for this feature to operate Override Enables the extractor to operate fully with or without either DC voltage input or the Volt free input The override feature can be toggled On Off by a switch mounted on the front panel see sectio...

Page 11: ... Motor Speed Adjustment The motor speed can be adjusted by the buttons on the front of the extraction unit Pressing the Up arrow will increase the motor speed Pressing the Down arrow will decrease the motor speed The 6 blue LED s on the front of the unit will display the motor speed there are several increments between each LED so the button may need to be pressed several times to illuminate the n...

Page 12: ...e a year to prevent build up of dust and overheating of the unit Replacing the Filters The filters will need changing when the Green LED on the front of the unit starts to flash Red At this point the Pre filter bag should be changed if the Green LED has not returned then the HEPA filter should also be changed A log of the changes should be maintained by the user The filters require attention when ...

Page 13: ...latches on the front of the extractor to open the front door 3 Undo the 2 screws that hold the filter cage in place 4 Remove the filter from its holder 5 Once removed it is recommended that the filters are bagged and sealed 6 Install the new filter and fit the filter cage 7 Close the door and secure the 2 latches 8 Reconnect the mains supply to the unit 02 6 ...

Page 14: ...trial Estate Poole Dorset BH17 7DU UK Phone 44 0 1202 699 444 Email Technical bofa co uk Website www Bofa co uk OR BOFA Americas 303 S Madison Street Staunton Illnois 62088 USA Phone 1 618 205 5007 Email info bofaamericas com Website www bofaamericas com OR BOFA International Germany Sudring 62 D 21465 Wentorf bei Hamburg Germany Phone 49 0 40 7393735 15 01 7 ...

Page 15: ...eer Filter disposal The filters are manufactured from non toxic materials Filters are not re usable cleaning used filters is not recommended The method of disposal of the used filters depends on the material deposited on them For your guidance Deposit EWC Listing Comment Non Hazardous 15 02 03 Can be disposed of as non hazardous waste Hazardous 15 02 02M The type of hazard needs to be identified a...

Page 16: ...sor fitted Hertz 50 60Hz Full Load Current 12 5A Noise Level Below 74dB A at maximum speed Size Metric mm Imperial inches Height 757 29 80 Depth 676 26 61 Width 880 34 64 Filters Filter Type Efficiency Pre filter 95 0 9micron HEPA 99 997 0 3micron Environmental operating range Temperature 5o C to 40o C Humidity Max 80 RH up to 31o C Max 50 RH at 40o C 01 9 ...

Page 17: ...Creekmoor industrial Estate Poole Dorset BH17 7DU UK Phone 44 0 1202 699 444 BOFA Americas 303 S Madison Street Staunton Illnois 62088 USA Phone 1 618 205 5007 BOFA International Germany Sudring 62 D 21465 Wentorf bei Hamburg Germany Phone 49 0 40 7393735 15 ...