background image

12

Overview

Specifications 

General specifications:

AC power source/power

AC adapter, 230 or 115 V,

requirements

+ 15%...–20%

Frequency

48–60 Hz

Power requirements,
direct current

V

10 to 20

Adaption to ambient 

By selection of 1 of 4 optimized

conditions

filter levels

Display update (depends on 
the filter level selected)

0.1–0.4

Specifications for the individual models:

BBL Series

Model

BBL31

BBL32

Weighing capacity

g

210

120

Readability

mg

0.1

0.1

Tare range (subtractive)

g

210

120

Repeatability

±mg

0.1

0.1

Linearity

±mg

0.2

0.2

Sensitivity drift within
+10…+30 °C/+50…+86°F

±/K

2·10

–6

2·10

–6

Response time (average)

s

3

3

External calibration weight

g

200 (E2) 100 (E2)

(of at least accuracy class…)

lb

0.4 (E2)

0.2 (E2)

Net weight, approx.

kg

3.0

3.0

Pan size

mm

80 Ø

80 Ø

Power consumption (average) W

1.0

Operating temperature range

+10…+30 °C (273…303 K) 
(50…86 °F)

Dimensions (W

×

D

×

H)

mm

189

×

251

×

300

BBL Series

Model

BBL42

BBL52

BBL53

BBL54

Weighing capacity

g

150

1,500

610

310

Readability

g

0.001

0.01

0.01

0.01

Tare range (subtractive)

g

150

1,500

610

310

Repeatability

±g

0.0015

0.015

0.01

0.01

Linearity

±g

0.003

0.03

0.02

0.02

Sensitivity drift within
+10…+30 °C/+50…+86°F

±/K

3.3·10

–6

3.3·10

–6

0.5·10

–5

1·10

–5

Response time (average)

s

2.5

2.5

2

2

External calibration weight

g

100 (F1) 1000 (F1) 500 (F2) 100(F2)

(of at least accuracy class…)

lb

0.2 (F1)

2 (F1)

1 (F2)

0.2 (F2)

Net weight, approx.

kg

1.6

1.4

1.1

1.1

Pan size

mm

100 Ø

150 Ø

115 Ø 

115 Ø

Hours of operation: 
– with 9-volt battery, approx. 

h

11

11

– with fully charged rechargeable

9-volt battery, approx.

h

2.5

2.5

Power consumption (average) W

0.75

Operating temperature range

0…+40 °C (263…313 K, 32 °F…104 °F)

Dimensions (W

×

D

×

H)

mm

189

×

251

×

70 

(without glass draft shield cylinder)

BBL Series

Model

BBL61 BBL62 BBL63 BBL64 BBL71

Weighing capacity

g

6,100

3,100

1,500

610

6,000

Readability

g

0.1

0.1

0.1

0.1

1

Tare range (subtractive)

g

6,100

3,100

1,500

610

6

Repeatability

±g

0.1

0.1

0.1

0.1

1

Linearity

±g

0.2

0.2

0.2

0.2

2

Sensitivity drift within
+10…+30 °C/+50…+86°F

±/K 0,5·10

–5

1·10

–5

2·10

–5

5·10

–5

5·10

–5

Response time (average)

s

2

2

2

2

2

External calibration weight

g

5,000

1,000

1,000

500

5,000

(of at least accuracy class…)

(F2)

(F2)

(M1)

(M1)

(M1)

lb

10,000 2,000 2,000

1,000

10,000

(F2)

(F2)

(M1)

(M1)

(M1)

Net weight, approx.

kg

1.4

1.4

1.4

1.4

1.4

Pan size

mm

150 Ø

Hours of operation: 
– with 9-volt battery, approx.

h

11

11

11

11

11

– with fully charged 

rechargeable 9-volt battery, 
approx.

h

2.5

2.5

2.5

2.5

2.5

Power consumption (average) W

0.75

Operating temperature range

0…+40 °C (263…313 K, 32 °F…104 °F)

Dimensions (W

×

D

×

H)

mm

189

×

251

×

70 

(without glass draft shield cylinder)

C

Marking

The 

C

marking affixed to the equipment indicates that the

equipment meets the requirements of the following Directive(s):

Council Directive 89/336/EEC 
“Electromagnetic compatibility (EMC)”

Applicable European Standards:

Limitation of emissions:
According to Product Standard EN61326-1 Kl.B
(Residential environment)

Defined Immunity to Interference:
According to Product Standard EN61326-1 
(Industrial environment)

Important Note:
The operator shall be responsible for any modifications to
BOECO equipment and for any connections of cables or
equipment not supplied by BOECO and must check and, 
if necessary, correct these modifications and connections.
On request, BOECO will provide information on the minimum
operating specifications (in accordance with the Standards
listed above for defined immunity to interference).

Council Directive 73/23/EEC 
“Electrical equipment designed for use within 
certain voltage limits”

Applicable European Standards:

EN 60950

Safety of information technology equipment 
including electrical business equipment

EN 61010

Safety requirements for electrical equipment
for measurement, control and laboratory use 
Part 1: General requirements

If you use electrical equipment in installations and under
ambient conditions requiring higher safety standards, 
you must comply with the provisions as specified in the 
applicable regulations for installation in your country.

Summary of Contents for BBL series

Page 1: ...BOECO 98648 012 04 BBL Models Electronic Precision Balances and Gold Scales Operating Instructions Modelos BBL Balanzas electr nicas de precisi n para metales preciosos Manual de instrucciones...

Page 2: ...2 English page 3 Espa ol p gina 13...

Page 3: ...ee operation of your balance Make sure that the voltage rating printed on the AC adapter is identical to your local line voltage Use only a commercially available 9 volt battery or rechargeable batter...

Page 4: ...aft shield faces upwards and turn it until it is firmly in place Pan support Weighing pan Glass draft shield Draft shield cover Balances with a Round Weighing Pan 115 mm Place the components listed be...

Page 5: ...isplay 1 Turn on the balance ON OFF Self test is performed 2 Place container on balance 52 0 g here 52 g 3 Tare the balance t 0 0 g 4 Place sample in container 150 2 g on balance here 150 2 g Calibrat...

Page 6: ...2 1 4 Reference sample quantity 20 pcs 3 3 3 Step Key or instruction Display 1 Turn on the balance ON OFF 2 Tare the balance t 0 0 g 3 Display the reference FUNCTION ref 20 briefly sample quantity 2 s...

Page 7: ...ng operations or subweighs Available Features The measured result displayed is the arithmetic mean shown in the selected weight unit a triangle under the plus or minus sign indicates that this is a ca...

Page 8: ...two weight units Configure the Toggle weight units application in the operating menu See Configuration menu code 2 1 2 Toggle weight units Menu code Unit Conversion factor Abbr on printout 1 7 2 o 3 1...

Page 9: ...ctory setting User setting Menu 1 Balance 1 1 Adapt filter 1 1 1 Minimum vibration functions 1 1 2 o Normal vibration 1 1 3 Strong vibration 1 1 4 Extreme vibration 1 3 Stability range 1 3 1 1 4 digit...

Page 10: ...ro is displayed not met e g balance not zeroed Press t to tare the balance balance is loaded Unload the balance e 09 When gross zero no tare Tare the balance e 10 The t key is blocked Press CAL CF 2 s...

Page 11: ...urn off the power and disconnect the equipment from AC power immediately Lock the equipment in a secure place to ensure that it cannot be used for the time being Safe operation of the balance with the...

Page 12: ...1 0 1 0 1 0 1 1 Linearity g 0 2 0 2 0 2 0 2 2 Sensitivity drift within 10 30 C 50 86 F K 0 5 10 5 1 10 5 2 10 5 5 10 5 5 10 5 Response time average s 2 2 2 2 2 External calibration weight g 5 000 1 0...

Page 13: ...ertencias para un funcionamiento seguro y sin problemas de la balanza el valor de tensi n impreso en el adaptador de CA debe concordar con la tensi n de red local utilizar s lo bater as block de 9 vol...

Page 14: ...tor de vidrio contra las corrientes de aire tapa superior con el borde hacia abajo Balanzas con platillo de pesada redondo 115 mm Montar componentes soporte del platillo de pesada platillo de pesada B...

Page 15: ...x 30 min despu s de la conexi n a la red Reci n entonces la balanza ha alcanzado la temperatura necesaria de funcionamiento Ejemplo Determinar valor de peso Ajustes previos los ajustes de f brica Paso...

Page 16: ...2 1 4 Cantidad piezas de referencia 20 c digo 3 3 3 Paso Pulsar tecla Indicaci n salida 1 en caso dado ON OFF encender bal 2 en caso dado t 0 0 g tarar balanza 3 informaci n indicar FUNCTION ref 20 br...

Page 17: ...tm tico aparece como lectura definitiva en la unidad de peso seleccionada e identificado mediante tri ngulo La cantidad de mediciones puede ser ajustada en el men ver en Ajustes previos La indicaci n...

Page 18: ...idades diferentes Ajustar en el men programa de aplicaci n Conmutaci n de unidades ver en Ajustes previos c digo 2 1 2 Conmutaci n de unidades Item de men Unidad Conversi n S mbolo 1 7 2 o 3 1 2 o Gra...

Page 19: ...s sinopsis o ajuste de f brica ajuste de usuario Men 1 Pesar 1 1 Adaptaci n 1 1 1 ambiente muy de filtro tranquilo 1 1 2 o ambiente tranquilo 1 1 3 ambiente intranquilo 1 1 4 ambiente muy intranquilo...

Page 20: ...pesada no fue observada p ej tare con la tecla t puesta a cero calibre con lectura cero platillo con carga e 09 con bruto cero sin tara Tare la balanza e 10 tecla t bloqueada con reci n despu s de bor...

Page 21: ...CA de la tensi n de red asegure la balanza contra el uso ulterior Un funcionamiento libre de riesgo del adaptador de CA ya no se garantiza si el adaptador de CA presenta da os visibles el adaptador de...

Page 22: ...ibilidad g 0 1 0 1 0 1 0 1 1 Rango de tara substractivo g 6100 3100 1500 610 6 Repetibilidad g 0 1 0 1 0 1 0 1 1 Linealidad g 0 2 0 2 0 2 0 2 2 Deriva de sensibilidad dentro de 10 30 C K 0 5 10 5 1 10...

Page 23: ...98648 012 04 Publication No WXX6050 al03091 W1A000 BOECO BBL GmbH Co scientific equipment Brandstwiete 4 20457 Hamburg t 040 3256270 f 040 32562741 E Mail Boeckel Co t online de Boeckel Co...

Reviews: