Application Programs

Counting

Purpose

With the Counting program you can determine the number 
of parts that each have approximately equal weight.

Available Features

– Store the current weight value to have it loaded as the 

preset reference sample quantity next time you initialize
the Counting application

– The reference sample quantity can be changed in the

operating menu:  See “Configuration”

– The average piece weight is automatically output via the

optional data interface port after initialization, if the menu
code for “Printout with data ID codes” is set

– Press [FUNCTION] to toggle the display between piece

count and weight

Factory Settings

Reference sample quantity:  10 (menu code 

3. 3. 2

)

Preparation

§

Configure the Counting application in the operating menu:  
See “Configuration” 
Menu code 

2. 1. 4

Counting

§

Reference sample quantity:
Menu code 

3. 3. 1

5 pcs

Menu code 

3. 3. 2

10 pcs

Menu code 

3. 3. 3

20 pcs

Menu code 

3. 3. 4

50 pcs

Menu code 

3. 3. 5

100 pcs

See also “Configuration”

Example

Determine an unknown piece count; weigh the preset 
reference sample quantity

Settings (changes in the factory settings required for 
this example):

Menu: Application program:  Counting (

2 1 4

)

Reference sample quantity:  20 pcs (

3. 3. 3

)

Step

Key (or instruction) Display

1. Turn on the balance

[ON/OFF] 

2. Tare the balance 

t

0.0

g

3. Display the reference 

[FUNCTION] 

ref  20

(briefly)

sample quantity 

> 2 sec.

(here:  20 pcs)

4. Place the reference sample

+

66.0

g

quantity (20 pcs) on the
balance (here:   66 g)

5. Start the application; 

[FUNCTION]

+

20

pcs

if the print format is set 
to include data ID codes, 
the following is printed

wRef

+

3.300 g

6. Weigh uncounted parts

+

174

pcs

(here: 174 pcs)

7. Display weight

[FUNCTION]

+

574.2

pcs

8. Display quantity

[FUNCTION]

+

174

pcs

9. Unload the balance

0

pcs

10. Delete the reference 

value

[CAL/CF] > 2 sec.

11. Repeat the procedure 

starting from Step 6, 
if desired.

Weighing in Percent 

Purpose

This application program allows you to obtain weight read-
outs in percent which are in proportion to a reference weight.

Available Features

– Store the current weight value to have it loaded as 

the preset reference percentage next time you initialize 
the Weighing in Percent application

– The reference percentage can be changed in the 

operating menu:  See “Configuration”

– The reference percentage is automatically output via the

optional data interface port after initialization, if the menu
code for “Printout with data ID codes” is set

– Press [FUNCTION] to toggle the display between 

percentage and weight

Factory Settings

Reference percentage:  10 (menu code 

3. 3. 2

)

Summary of Contents for BBL series

Page 1: ...BOECO 98648 012 04 BBL Models Electronic Precision Balances and Gold Scales Operating Instructions Modelos BBL Balanzas electr nicas de precisi n para metales preciosos Manual de instrucciones...

Page 2: ...2 English page 3 Espa ol p gina 13...

Page 3: ...ee operation of your balance Make sure that the voltage rating printed on the AC adapter is identical to your local line voltage Use only a commercially available 9 volt battery or rechargeable batter...

Page 4: ...aft shield faces upwards and turn it until it is firmly in place Pan support Weighing pan Glass draft shield Draft shield cover Balances with a Round Weighing Pan 115 mm Place the components listed be...

Page 5: ...isplay 1 Turn on the balance ON OFF Self test is performed 2 Place container on balance 52 0 g here 52 g 3 Tare the balance t 0 0 g 4 Place sample in container 150 2 g on balance here 150 2 g Calibrat...

Page 6: ...2 1 4 Reference sample quantity 20 pcs 3 3 3 Step Key or instruction Display 1 Turn on the balance ON OFF 2 Tare the balance t 0 0 g 3 Display the reference FUNCTION ref 20 briefly sample quantity 2 s...

Page 7: ...ng operations or subweighs Available Features The measured result displayed is the arithmetic mean shown in the selected weight unit a triangle under the plus or minus sign indicates that this is a ca...

Page 8: ...two weight units Configure the Toggle weight units application in the operating menu See Configuration menu code 2 1 2 Toggle weight units Menu code Unit Conversion factor Abbr on printout 1 7 2 o 3 1...

Page 9: ...ctory setting User setting Menu 1 Balance 1 1 Adapt filter 1 1 1 Minimum vibration functions 1 1 2 o Normal vibration 1 1 3 Strong vibration 1 1 4 Extreme vibration 1 3 Stability range 1 3 1 1 4 digit...

Page 10: ...ro is displayed not met e g balance not zeroed Press t to tare the balance balance is loaded Unload the balance e 09 When gross zero no tare Tare the balance e 10 The t key is blocked Press CAL CF 2 s...

Page 11: ...urn off the power and disconnect the equipment from AC power immediately Lock the equipment in a secure place to ensure that it cannot be used for the time being Safe operation of the balance with the...

Page 12: ...1 0 1 0 1 0 1 1 Linearity g 0 2 0 2 0 2 0 2 2 Sensitivity drift within 10 30 C 50 86 F K 0 5 10 5 1 10 5 2 10 5 5 10 5 5 10 5 Response time average s 2 2 2 2 2 External calibration weight g 5 000 1 0...

Page 13: ...ertencias para un funcionamiento seguro y sin problemas de la balanza el valor de tensi n impreso en el adaptador de CA debe concordar con la tensi n de red local utilizar s lo bater as block de 9 vol...

Page 14: ...tor de vidrio contra las corrientes de aire tapa superior con el borde hacia abajo Balanzas con platillo de pesada redondo 115 mm Montar componentes soporte del platillo de pesada platillo de pesada B...

Page 15: ...x 30 min despu s de la conexi n a la red Reci n entonces la balanza ha alcanzado la temperatura necesaria de funcionamiento Ejemplo Determinar valor de peso Ajustes previos los ajustes de f brica Paso...

Page 16: ...2 1 4 Cantidad piezas de referencia 20 c digo 3 3 3 Paso Pulsar tecla Indicaci n salida 1 en caso dado ON OFF encender bal 2 en caso dado t 0 0 g tarar balanza 3 informaci n indicar FUNCTION ref 20 br...

Page 17: ...tm tico aparece como lectura definitiva en la unidad de peso seleccionada e identificado mediante tri ngulo La cantidad de mediciones puede ser ajustada en el men ver en Ajustes previos La indicaci n...

Page 18: ...idades diferentes Ajustar en el men programa de aplicaci n Conmutaci n de unidades ver en Ajustes previos c digo 2 1 2 Conmutaci n de unidades Item de men Unidad Conversi n S mbolo 1 7 2 o 3 1 2 o Gra...

Page 19: ...s sinopsis o ajuste de f brica ajuste de usuario Men 1 Pesar 1 1 Adaptaci n 1 1 1 ambiente muy de filtro tranquilo 1 1 2 o ambiente tranquilo 1 1 3 ambiente intranquilo 1 1 4 ambiente muy intranquilo...

Page 20: ...pesada no fue observada p ej tare con la tecla t puesta a cero calibre con lectura cero platillo con carga e 09 con bruto cero sin tara Tare la balanza e 10 tecla t bloqueada con reci n despu s de bor...

Page 21: ...CA de la tensi n de red asegure la balanza contra el uso ulterior Un funcionamiento libre de riesgo del adaptador de CA ya no se garantiza si el adaptador de CA presenta da os visibles el adaptador de...

Page 22: ...ibilidad g 0 1 0 1 0 1 0 1 1 Rango de tara substractivo g 6100 3100 1500 610 6 Repetibilidad g 0 1 0 1 0 1 0 1 1 Linealidad g 0 2 0 2 0 2 0 2 2 Deriva de sensibilidad dentro de 10 30 C K 0 5 10 5 1 10...

Page 23: ...98648 012 04 Publication No WXX6050 al03091 W1A000 BOECO BBL GmbH Co scientific equipment Brandstwiete 4 20457 Hamburg t 040 3256270 f 040 32562741 E Mail Boeckel Co t online de Boeckel Co...

Reviews: