Figure 29
Figure 28
SET SCREW
RED RESET
BUTTON
NO PRESSURE ON
LOAD CELL
1 MM BETWEEN SET SCREW
AND LOAD CELL
COUNTER NUT
LOAD CELL
BRACKET
Figure 27
15
CALIBRATION
BODY BIKE Connect is able to
measure extremely accurate
due to the unique brake unit.
When replacing the brake unit
it can be necessary to adjust the
set screw in order to obtain full
advantage of the high level of
accuracy.
1: Remove the right service
hatch, see fi gure 15 on page 10.
2: Release all tension and push
the brake unit back on the shaft,
see fi gure 27.
3: Slowly add tension without
touching the brake unit. The
brake unit will automatically
move forward on the shaft
until the brake block arc settles
on the fl ywheel curvature. If
the brake unit does not move
forward it has already settled on
the fl ywheel.
4: When the brake unit has
settled, adjust the set screw to
obtain 1mm space between the
load cell and the set screw, see
fi gure 28. Tighten counter nut.
Move the load cell bracket if the
adjustment of the set screw is
not adequate. Be careful not to
overload the load cell by pulling
or twisting it.
5: Tighten the counter nut, see
fi gure 28.
6: 0-calibrate the load cell by
pressing the red reset button on
the control box, see fi gure 29.
Make sure nothing is pressing on
the load cell when 0-calibrating.
7: Remount the service hatch.
BODY
BIKE
®
I N DOOR C YC L E
15
M
AINTENANCE