See Figure 1 on page 5. Also see Section 4 – Important Application Information, on pages 20 – 22.
WARNING! Disconnect main power when making connections to the drive.
1.1
AC Line Connection –
Wire the single-phase AC line input to Terminals “L1” and “L2”, as
shown in Figure 16, on page 31. See Section 9.1, on pages 30 and 31.
Application Note: Do not wire this drive to a GFCI. If operation with a GFCI is required,
contact our Sales Department.
Model 2982 –
Rated for 115 Volt AC line input only.
Model 2983 –
Rated for 208/230 Volt AC line input only.
Models 2984, 2987 –
Rated for 208/230 Volt AC line input with Jumper J1 (on upper PC
board) set to the “230V” position (factory setting). Rated for 115 Volt AC line input with
Jumper J1 (on upper PC board) set to the “115V” position ).
1.2
Ground Connection –
Connect the ground wire (earth) to the ground screw, as shown in
Figure 16, on page 31. See Section 9.2, on page 31.
6
1
QUICK-START INSTRUCTIONS
Important –
You must read these simplified instructions before proceeding. These instructions
are to be used as a reference only and are not intended to replace the details provided herein.