2.2 Electrical installation
The wiring is different depending on the type of clock (single or double sided) and the type of
power supply (low voltage or 100-240V )
2.2.1 Low voltage power supply
Single-sided model:
POWER SUPPLY
6-24 V
+ -
- Strip the cable from the wall over 10 mm,
- Strip the two wires with a cross-section of 1.5 mm² (maximum) over 5 mm,
- Connect the wires directly to the terminal block on the back of the clock
(at the bottom of the movement) in the power supply terminals, 6-24 V ,
respecting the + / - polarity indicated on the label,
- Affix a cable retainer around the power supply wires.
1 cm
Remember, conductors on the same circuit must be attached to each
other close to the terminal block to avoid reduced isolation should
one of the terminals become loose.
Double-sided model:
- Route the wiring through the bracket arm,
- Wire the first clock
A
as a single-sided clock (see above),
- Wire the second clock
B
by making a cascade connection to the + / - power supply, 6-24 V
terminals of the first clock
A
.
A
B
EN