2 - ELECTRICAL INSTALLATION

2.1 - Configuration Wireless DHF/Wired

The DIP switch 2 is used to set 

the wireless Melodys in

wired version.

 

 

Warning : the operation is different 

according to the mode being used: 

in “Wireless DHF” mode, the master 

clock Sigma selects one melody 

among 16 while in  “Wired mode” the 

master clock turns on the Melodys 

which will play the last pre-selected 

(in the Melodys itself) melody.

 

2.2 - « Wireless DHF » mode installation

In accordance with the model, 1100-

240VAC ±10% 50/60 Hz or 24 VDC, 

connect the appropriate power supply 

on the terminal strip (2), As the device 

is a class II device, there is no 

earth 

connection.

The cable must be attached (point 4) 

in such a way as to place no stress 

on the connection terminals.

 

For a 24V installation, verify that 

the voltage does not drop below the 

threshold (24V-10%). The section of the 

line should be fitted to its consumption 

and length.

Melodys TBT 24V installation precaution: Maximum distance allowed

 Wire cross-sectional area (wire diameter)

0,5

2

 (8/10)

0,75

2

1,5

2

Number of Melodys on the line

15

43 m

62 m

125 m

10

62 m

95 m

190 m

5

125 m

190 m

380 m

 

Important notes: 

 

1 – The distance can be doubled by limiting the volume to 7.

2 – These distance limitations concern only one Melodys line; but it is possible to 

install several lines in parallel.

DIP switch 

positions

DIP2 to position 

off = wired version

 

DIP2 to position on 

= wireless version

2

4

Summary of Contents for BP30001

Page 1: ...EMENTINES Tél 33 241 71 72 99 Fax 33 2 41 71 72 01 Réf 607619 B www bodet time com Indoor Melodys Instructions for installing and use Check the product for shipping damage on reception for any reservations to the carrier MELODYS ...

Page 2: ...page 3 1 MECHANICAL INSTALLATION Ensure that power will be available where the sounder will be installed To open the casing of the sounder unscrew the screw 3 under the sounder and remove the cover remove the 2 screws 1 Carefully remove the front panel and disconnect the loudspeaker cable Secure the sounder in its location Make sure that the sounder is placed flat against the wall to prevent vibra...

Page 3: ...vice there is no earth connection The cable must be attached point 4 in such a way as to place no stress on the connection terminals For a 24V installation verify that the voltage does not drop below the threshold 24V 10 The section of the line should be fitted to its consumption and length Melodys TBT 24V installation precaution Maximum distance allowed Wire cross sectional area wire diameter 0 5...

Page 4: ...e DHF LED 6 flashing Set the Sigma master clock to INIT mode see the master clock manual Once the receiver is initialised the DHF LED is red to begin with and then green after reception of the DHF sounder commands from the master clock Note the DHF sounder commands are sent every hour and on each modification of the programming To reset to INIT mode simply press the TST key for 10 seconds Two LEDs...

Page 5: ...sounders use a contactor see the above illustration e g type Merlin Gerin reference 15373 If a 24V bell system has many sounders verify that the voltage does not drop below the threshold 24V 10 The section of the line should be fitted to its consumption and length Melodys TBT 24V installation precaution Maximum distance allowed Wire cross sectional area wire diameter 0 52 8 10 0 752 1 52 Number of...

Page 6: ...after fixing and reinstalling of the front panel FOperation of the sounder in wired mode The sounder is controlled by any programmer The LED indicates the presence of the power supply When the product is switched on the pre selected melody is played B A ...

Page 7: ...d D The green dot C at the bottom right of the readout indicates that the melody being played is a melody contained in the memory of the Melodys system The Melodys sounder support SD card and SDHC card An Optional SD Card is available to record and play other melodies mp3 file format The melodies on this SD Card replace the basic melodies of the sounder They can be recorded directly by the user fr...

Page 8: ...munity EN 300 220 2 Good use of the radio spectrum EN 55022 Information Processing Device emission standard EN 55024 Information Processing Device immunity standard DHF norm NF S 87 500 C single channel 869 525 MHz 500 mW Power supply according to model 100 240VAC 10 50 60 Hz 24 VDC 5 Dimensions H202 x W150 x D82mm Parameter backup permanent Operating temperature 0 to 50 C Protection index IP31 CL...

Reviews: