Specifications for ProScope Mobile

Compatible Host Devices

Apple iOS devices including iPhone, iPad, and iPod touch

Image sensor

1/4 inch 5Mp Color CMOS

Resolution

320x240 (QVGA) / 640x480 (VGA)

Capture

Still image capture by Application

White Balance

MWB

Gain

AGC

Frame Rate

QVGA about 15fps (It changes with radio wave environment and the use device.)

Camera button Functions

a) Still image capture

b) Push W/B after still image captured

c) QVGA/VGA exchange

d) Initialize for factory settings

(Maintained after power supply is switched OFF)

Indicator LED

ON: The image is being transmitted

OFF: Power OFF or Battery is low

Flash 0.5sec: The W/B is being changed

Flash 1sec: The resolution is being changed

Flash 2sec: Initialize for factory settings

Light Switch

A-OFF-B (depends on the attached lens)

A: OFF, or reflective LEDs

OFF:OFF

B: Reflective LEDs, or Non Reflective LEDs

Power Switch

ON/OFF Slide switch

Magnification

X50 (when standard lens is used) Approximate magnification when displayed on 14-inch 

monitor.

Support Protocol

Wi-Fi  IEEE802.11b 

Camera Operational Range

about 10m from a Wi-Fi connected device

Access Format

ad hoc mode

Antenna

Internal Chip Multilayer antenna

Frequency

2.4GHz band width

SSID

AirMicroNNN

IP Address

192.168.NNN.1

Camera Screw

1/4-20 UNC

Battery

AA(Alkaline,Ni-MH)x3

Power Consumption

about 2.5W with standard lens

Continuous Operation time

Alkaline: about 2 hours, Ni-MH about 3 hours with standard lens.  

(Depends on environment)

Lens Mount

Standard ProScope Mount

Supply Current: A and B about 5V 120mA

Operation Temp

0ûC~40ûC

Storage Temp

-10ûC~60ûC

Outside Dimensions

153mm(H)x46mm(W)x43mm(D) (without Lens)

Weight

130g (without battery, with Lens)

Patented Technology

US Patent 5,442,489

Regulatory Compliance

FCC, CE Compliant

*

Specifications subject to change without notice.

6 0 7 7 A   S W   L a k e v i e w   B l v d .

L a k e   O s w e g o ,   O R   9 7 0 3 5

w w w . b o d e l i n . c o m

s u p p o r t @ b o d e l i n . c o m

8 0 0 - 4 4 1 - 6 8 7 7

**Important: The ProScope Mobile only works on Apple iOS devices including iPhone, iPad 

and iPod touch. This device DOES NOT WORK with Mac or PC computers.

12

Science Services GmbH
Unterhachinger Str. 75
81737 Munich, Germany
Tel: +49 (0)89 18 93 668 0 

 Fax: +49 (0)89 18 93 668 29

Mail: [email protected] 

 Web: ScienceServices.de

Your Partner for Microscopy and Lab Supplies

Summary of Contents for ProScope Mobile

Page 1: ...10 FAQ and Troubleshooting 11 Wi Fi handheld microscope for use with the Apple iPhone iPod touch or iPad iPhone iPod touch and iPad are registered trademarks of Apple Inc Specifications 12 Image Adjus...

Page 2: ...PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED INCLUDING INTERF...

Page 3: ...Indicator Indicates power is ON 5 Tripod Mount Connect to ProScope stand or any standard tripod 6 Camera Button Still picture capture or freeze 7 Battery Cover For battery access and installation 8 P...

Page 4: ...rt 3 AA batteries Battery cover removed Insert 3 AA batteries paying attention to the polarity You may use alkaline or Ni MH Do not mix battery types or mix new batteries with old batteries Rechargeab...

Page 5: ...e ProScope Mobile camera follow these steps 1 On your device choose Settings 2 Turn Wi Fi ON 3 Select AirMicro from the wireless network menu Every ProScope Mobile unit can be different in this exampl...

Page 6: ...selectable value between 2 254 which represents a unique IP address for this device In this example the IP Address is 192 168 119 100 Input Subnet Mask 255 255 255 0 Note if your AirMicro network numb...

Page 7: ...ur camera the searching screen will appear until it finds the camera Note if the searching screen persists check to make sure your AirMicro network is the active Wi Fi network selected After the ProSc...

Page 8: ...is QVGA 320X240 but can be changed to VGA 640X480 To toggle between QVGA and VGA do the following With the main Power Switch in the OFF position press and hold the Camera Button while turning the Pow...

Page 9: ...you can then gently pull the lens straight up and off Installing a Lens To install a lens line up the hash mark on the lens and the hash mark on the ProScope Mobile body then press down gently until t...

Page 10: ...b or microfiber cloth but do not use paper Wipe only in one direction so the debris is swept off the imager rather than just moved around Finish with a light blast of compressed air to remove any loos...

Page 11: ...multitasking bar at the bottom of the screen If you don t initially see the AirMicro app flick left to see more apps To force the AirMicro app to close Touch and hold the app icon until it begins to...

Page 12: ...nge about 10m from a Wi Fi connected device Access Format ad hoc mode Antenna Internal Chip Multilayer antenna Frequency 2 4GHz band width SSID AirMicroNNN IP Address 192 168 NNN 1 Camera Screw 1 4 20...

Reviews: