Malfunction
,
CODE*
Error message
Possible cause
Troubleshooting:
Repair by
NO7
Side door ‘C’
a) Door ‘C’ is not
properly closed
b) Connector of door
‘C’ not plugged in
c) Door ‘C’ not installed
– blind plug not
inserted
d) Door ‘C’ limit switch
faulty
a) Close door ‘C’ properly
b) Plug in connector of door
‘C’
c) Door ‘C’ not installed –
insert blind plug
d) Replace door ‘C’ limit
switch
a) US
a) US
c) US
d) TE
NO8
Door lock
a) pivoting door support
leg 1 or 2 jammed and
is not locked
b) pivoting door support
leg 1 or 2 not inserted
c) pivoting door support
leg 1 or 2 not installed -
blind plug not inserted
d) Limit switch for
pivoting door support
leg 1 or 2 faulty
a) Ensure pivoting door
support leg 1 or 2 operates
smoothly
b) Insert connector for pivoting
door support leg 1 or 2 is
inserted
c) Pivoting door support leg 1
or 2 not installed - insert blind
plug
d) Replace limit switch for
pivoting door support leg 1 or
2
a) US
a) US
c) US
d) TE
NO9
M overheated
a) Motor
– motors
overheated
a) Use manual venting system
to lower lift. After the motor
has cooled off, the drive may
continue
if necessary check if power
supply is too low
a) LO
NO10
Installation hatch
a) Installation
hatches/mounting aids
are not locked properly
b) Limit switches of
installation
hatches/mounting aids
faulty
a) Lock installation
hatches/mounting aids
b) Replace limit switches of
installation hatches/mounting
aids
a) US
b) TE