7.4.6
FL20K foreline trap
The foreline trap minimises oil vapour
backstreaming from the backing pump and is
recommended where the highest system cleanliness
is required.
Foreline trap
Item Number
FL20K
A133-05-000
Table 16 - FL20K foreline trap
7.4.7
TAV vent-valve and vent-port
adaptor
Two solenoid-operated vent-valves are available for
system venting. The valves are 24 V dc, normally-
open, and can be driven automatically from the EXC
Controller. The solenoid-valve is fitted in place of
the manual-valve, or alternatively can be fitted with
an adaptor (supplied with the valve) and be used
with any suitable NW10 flanged port on your
vacuum system.
The vent-port adaptor allows the vent-port or the
purge-port to be used with any suitable NW10
fitting: refer to Figure 5.
Product
Item Number
TAV5 vent-valve
B580-66-010
TAV6 vent-valve
B580-66-020
NW10-1/8 inch BSP
male adaptor
B580-66-011
Table 17 - TAV vent-valve and vent-port adaptor
7.4.8
ACX air-cooler
An ACX air-cooler can be fitted to the EXT pump.
However, please refer to Section 3.7 and to Table 5
to check the suitability of air-cooling in a particular
application.
Pump
Air-cooler
Item Number
EXT555H/Hi
ACX555
B580-53-561
Table 18 - ACX air-cooler
Summary of Contents for EXT555H
Page 1: ...NRA 266 880 Issue A Original 98 37 EC 89 336 EEC 73 023 EEC Instruction Manual EXT555H...
Page 2: ......
Page 6: ...Issue A Jun 01 EXT555H PAGE iv iv This page intentionally blank...
Page 8: ...Issue A Jun 01 EXT555H PAGE 2 2 This page intentionally blank...
Page 24: ...Issue A Jun 01 EXT555H PAGE 18 18 This page intentionally blank...
Page 32: ...Issue A Jun 01 EXT555H PAGE 26 26 This page intentionally blank...
Page 40: ...Issue A Jun 01 EXT555H PAGE 34 34 This page intentionally blank...
Page 43: ......