![BOC Edwards EXT555H Instruction Manual Download Page 15](http://html1.mh-extra.com/html/boc-edwards/ext555h/ext555h_instruction-manual_2781980015.webp)
Jun 01
Issue A
EXT555H
IN
STALL
A
TION
PAGE
9
9
3
INSTALLATION
3.1
Unpack and inspect
Take care when you unpack the pump to avoid
excessive shocks which could damage the bearings
and reduce the life of the pump. The pump is
supplied with the inlet and the outlet sealed to
prevent entry of dust and vapour. Do not remove
these seals until you are ready to install the pump on
your vacuum system.
Remove all the outer cardboard packaging and
check the pump. If the pump is damaged, notify your
supplier and carrier in writing within three days;
state the item number of the pump together with
your order number and your supplier's invoice
number. Retain all the packing materials for
inspection. Do not use the pump if it is damaged.
Check that your package contains the items listed in
Table 6. If any of these items is missing, notify your
supplier in writing within three days.
If the pump is not to be used immediately, store the
pump in suitable conditions as described in
Section 6.1.
It is advised that you retain all packing materials for
use should you return the pump for service.
WARNING
The EXT555H DN160CF pump
variant weighs 21 kg. Take care when
handling the pump and ensure that
you grip it firmly by the inlet flange
when manoeuvring it.
3.2
Typical installation
A typical pump system with an EXT555H pump is
shown in Figure 1.
The accessories available for the EXT555H pump
are detailed in Section 7.4. The accessories are
shown in Figure 5.
3.3
Connection to the vacuum system
Carefully remove the pump from packaging media
and connect to the vacuum system
.
3.3.1
Inlet screens (supplied fitted)
WARNING
Install the pump on the vacuum
system before you connect the
controller to the power supply. This
will ensure that the pump cannot
operate and injure people during
installation.
WARNING
Removal of inlet screens will expose
people to the risk of injury from
sharp edges.
CAUTION
Removal of inlet screens could allow debris to fall
into the pump, which could cause serious damage
to the pump.
Qty
Description
1
EXT555H turbomolecular pump
1
Inlet screen (fitted)
1
Inlet seal (trapped 'O' ring, co-seal or copper compression gasket)
1
Inlet strainer (EXT555Hi only, fitted in the interstage port)
Table 6 - List of items supplied
Summary of Contents for EXT555H
Page 1: ...NRA 266 880 Issue A Original 98 37 EC 89 336 EEC 73 023 EEC Instruction Manual EXT555H...
Page 2: ......
Page 6: ...Issue A Jun 01 EXT555H PAGE iv iv This page intentionally blank...
Page 8: ...Issue A Jun 01 EXT555H PAGE 2 2 This page intentionally blank...
Page 24: ...Issue A Jun 01 EXT555H PAGE 18 18 This page intentionally blank...
Page 32: ...Issue A Jun 01 EXT555H PAGE 26 26 This page intentionally blank...
Page 40: ...Issue A Jun 01 EXT555H PAGE 34 34 This page intentionally blank...
Page 43: ......