Hanging bracket dimensions 
 

Model

 

Dimension A 

HCA-09 

787 

HCA-13 

1295 

HCA-18 

1795 

All dimensions in millimetres. 
M6 bracket wall fixings not included 
 

CONSTRUCTION 

 
Handling and Storage 
Door curtains and accessories are individually packaged in 
cardboard  cartons,  two/three  persons  can  usually  handle 

the  heaviest  door  curtain.  Under  no  circumstances  should 
you  try  and  lift  the  Door  curtain  on  your  own.  When  a 
significant quantity of door curtains are delivered, they may 
be palletised and shrink-wrapped, so a fork-lift or similar will 
be  required  for  lifting.    The  door  curtain(s)  must  not  be 
dropped or suffer impact in any circumstances.

  

 

Storage 
Door curtains should be stored in clean, dry conditions. Any 

packaging should not be removed until the  door curtain is 
required  for  installation.    Packaging  should  only  be 
removed if damage is suspected at the time of delivery. 
 
 
 

  

WARNING 

Some  components  on  the  door  curtain  may  have  sharp 
edges. Care must be taken when handling the product and 
protective gloves should be worn. 
 

 
Preparation 
Provision must be made for proper fixings. The ceiling 

or  soffit  must  be  suitable  to  accept  fixings  such  as 
expanding anchors and/or drop rods. 
 
Access  is  required  for  maintenance  i.e.  electrical 
connections  and  removal  of  door  curtain  outer 
casing.   
 
Approximate Weight 
 

Model

 

Weight (kg) 

HCA-09 

19.6 

HCA-13 

25.4 

HCA-18 

31.9 

 

14

0

 

R3.

5

 

Ø7.

0

 

3
0

 

DIM.A 

Summary of Contents for HCA

Page 1: ...consist of a casing motor tangential fan s electric heating elements and electrical connection box Each door curtain is supplied with a wall mounting bracket and a remote switching control box as stan...

Page 2: ...off until the air temperature in the casing drops below 50 C or will switch the fan back on after the unit is turned off should the case temperature rise above 50 C for a short period The other manual...

Page 3: ...m above connection details View from front return air inlet grille View from below air supply discharge grille View from side All dimensions in millimetres Model Dimension A HCA 09 1113 HCA 13 1621 HC...

Page 4: ...t be dropped or suffer impact in any circumstances Storage Door curtains should be stored in clean dry conditions Any packaging should not be removed until the door curtain is required for installatio...

Page 5: ...n and operation observe minimum spacing to wall and soffit surface shown in diagram 4 Position of the power supply connections are to be taken into consideration during installation 5 Connect electric...

Page 6: ...Holes to accept mounting bracket fixing bolts tabs to be folded out on site Slots to accept mounting bracket Wall mounted installation 110mm minimum A Locking washers provided M4 fixing bolts provide...

Page 7: ...stances 110mm minimum 18mm Tabs to be folded out on site View from above Ceiling suspended installation View from above electrical connections Safety cut out manual reset switch 2 off 25 holes to acce...

Page 8: ...8...

Page 9: ...e switch You MUST connect the live connection in the timer to Terminal 7 inside the Air curtain If you don t there is a possibility that 400v may be present inside the time switch making it unsafe Whe...

Page 10: ...e 0 75mm 3 core cable 3rd core if earth connection required You MUST first remove the link between A1 and B4 on switch S1 On Off Switch and replace with the thermostat as shown in the drawing below Wh...

Page 11: ...lements do not require any maintenance other than a visual inspection however when cool they may be vacuumed clean to remove dust using a soft bush attachment Fuse The mains inlet connector incorporat...

Reviews: