bmb-home HOME PROTECTOR+ User Manual Download Page 25

 

P/N 033000=13610 Rev. 01-02-06                                                                                                               BMB Home Security

 

25 

Universal Siren  

Connect an own siren to a AM12 or 

 

B6 (=HC+1, UC=6) 

 

 

AD10 module.  

 
H.A. Automation  

H.A. functions in respond to sensor (27-32)    

B7 – B12   

 

 

when in ARMED mode and triggered. 

 

(=HC+1, UC=7-12). 

 
Thermostats  

Thermostat H.A. addresses.  

 

 

B13 – B16  
(=HC+1, UC=13-16). 

 
*This table uses the unchanged settings (House Code + Unit Code) for the basic console address. The default 
base address is A1. 

 
10.6 Basic address for Home Automations functions 

The basic address is set to control multiple Home Automation modules on the SC28. The standard basic 
address is A1. The A in this address is called the House Code. The House Code of the console, the remote 
controls and the Home Automation modules all have to have the same letter. The 1 in the basic address is called 
the Unit Code. If your neighbours also have a security system, it may be necessary to change the basic 
addresses and the addresses of your X10 modules. If you change the House Code of the console, the 
addresses for the Home Automation functions (10.5) also change.  
 
To change the House Code: 
1. To access the menu, press the menu UP?

 

or menu DOWN button. The display now shows 

ENTER PIN. 

2. Enter your 4-digit PIN code (factory setting 0000. See 8.3 for changing the PIN code). The display is cleared 
and shows a * for each number entered. 
3. When the PIN code has been entered correctly, the word 

INSTALL

 will show up on the display. 

4. Use the menu buttons UP/DOWN?

 

to go to menu item 

7. OPTIONS

. Press OK to select this menu item. You can 

also go to this menu item directly by pressing a 7 on the number pad. 
5. Use the menu buttons UP/DOWN?

 

to go to menu item 

HOUSECODE

. Press OK to select this menu item. 

6. Use the menu buttons UP/DOWN?

 

to select the desired House Code and press OK. 

7. Press CLEAR again to quit the menu. 
 
If you change the Unit Code of the console, the addresses for the Home Automation functions also change. To 
change the Unit Code: 
1. To access the menu, press the menu UP?

 

or menu DOWN button. The display now shows 

ENTER PIN. 

2. Enter your 4-digit PIN code (factory setting 0000. See 8.3 for changing the PIN code). The display is cleared 
and shows a * for each number entered. 
3. When the PIN code has been entered correctly, the word 

INSTALL

 will show up on the display. 

4. Use the menu buttons UP/DOWN?

 

to go to menu item 

7. OPTIONS

. Press OK to select this menu item. You can 

also go to this menu item directly by pressing a 7 on the number pad. 
5. Use the menu buttons UP/DOWN?

 

?

to go to menu item 

UNITCODE

. Press OK to select this menu item. 

6. Use the menu buttons UP/DOWN?

 

?

to select the desired Unit Code and press OK. 

7. Press CLEAR again to quit the menu. 
 

10.7 Thermostats, Remote Controlled Temperature Settings 

Each  registered  thermostat transmits the comfort set point  and the ambient temperature.  In the SC28  base 
station you can enter a  Comfort level per Thermostat as well as setbacks to Economy and Frost  temperature 
levels.  
 
When the Security Base Console is in "DISARM" or "ARM HOME" mode, it will turn On or Off the X10 module 
connected to  the  heater or  boiler depending on the ambient temperature  and the comfort set point set to the 
thermostat. When the ambient temperature is lower than the thermostat set-temperature, an ON-message to the 
corresponding address will be send.   
 
When the console is in "ARM AWAY" mode, the respective temperature point is applied as set to the thermostat, 
however there’s also an option to select the setback temperature levels set to the console which do apply for all 
registered thermostats.  
 
Suppose the ambient temperature is 20 

°

C, the comfort set point of the thermostat is 24

°

C the console will send 

an ON message. Suppose that now the ambient temperature is still 20

°

C, the economy setting is in place, set to 

15

°

C, the console will send an OFF message.  

If then a timed event is taking place, where COMFORT2 of thermostat 2 is set to 22

°

C, and ambient temperature 

measured by thermostat is still 20

°

C, the console will send an ON message to the respective HA address. (see 

chapter 7.8 for timed temperature 

°

 events). 

 

Summary of Contents for HOME PROTECTOR+

Page 1: ...WIRELESS SECURITY SYSTEM HOME PROTECTOR USERS MANUAL PROTECTOR SYSTEM AND BASE CONSOLE INSTRUCTIONS...

Page 2: ...P N 033000 13610 Rev 01 02 06 BMB Home Security 2 NOTES...

Page 3: ...Sensor to the wired input 4 2 Motion Detector MS18 4 2 1 Mounting the Motion Detector MS18 4 2 2 Using the Motion Detector 4 2 3 Registering a Motion Detector with the Console 4 3 Additional Wireless...

Page 4: ...utdoor usage should only be used inside and only in dry spaces Do not expose the components to rain or humidity Do not use the product close to a bath swimming pool etc Only connect the adapter to the...

Page 5: ...ole Includes 2 inputs for wired sensors zone 31 32 Selectable ALWAYS sensors for emergency purposes 2 Arm Home Modes by pressing ARM HOME once or twice ARM HOME once only D W sensors will be armed Sec...

Page 6: ...p batteries are empty or not installed 5 Tamper contact 6 AC power supply adapter connections 7 ARM HOME button Alarm function for when you are at home All Door Window Sensors are activated but the Mo...

Page 7: ...utside land line This 0 needs to be programmed in with the telephone numbers to be able to dial out see 5 2 2 1 2 Connecting the AC adapter Connect the AC adapter to the corresponding connection 6 Plu...

Page 8: ...sh for default You can choose any of the other available languages as follows To access the menu press the menu UP or menu DOWN button The display now shows ENTER PIN Enter the 4 digit PIN code factor...

Page 9: ...E ANSWER ON ANSWER OFF VOICE MAIL 11 2 SENSOR MODE Use sensors as emergency sensor See 9 5 SENSOR 27 32 NO ON OFF Used for setting zones 27 to 32 to send Home Automation ON or OFF commands on House Co...

Page 10: ...en a unique code which can be registered with your console When pressing the ARM button the LED should flash quickly a few times When the LED lights up and stays lit you need to re initialize the KR18...

Page 11: ...piece of paper behind the plastic cover of the text window you can note which Home Automation Modules can be controlled with each key 7 House Code Switch Used for setting the X10 system Address 3 2 1...

Page 12: ...nsmitter part on the frame of your door or window Do not close the casing yet 2 Mount the magnet on the moving part of your door of window Make sure that the arrows on the transmitter part see the arr...

Page 13: ...to confirm The display will read ZONE 1 SET A memory space for a sensor is called a zone If you have more than 1 sensor installed it will show e g ZONE 2 SET ZONE 3 SET ZONE 30 SET You can choose in w...

Page 14: ...n so that it can t detect any movement during registration Test mode Testing the location of your motion detector 1 Set the switch 5 to 1 2 Press the TEST button 6 until the indicator 1 flashes twice...

Page 15: ...nd or additional panic detectors based on remote panic function or up to 30 sensors in case of wireless alarm sensor function 6 Repeat step 5 for every additional sensor you wish to register 7 Press C...

Page 16: ...he display is cleared and shows a for each number entered 3 When the PIN code has been entered correctly the word INSTALL will displayed 4 Use the menu buttons UP DOWN to go to menu item 3 PHONE NUMS...

Page 17: ...elay will be used for DS18 Door Window Sensors DS18 switch set to MAX when you enter the house This means you have enough time to switch off the system via the console without triggering the alarm The...

Page 18: ...en DISARM You can also switch off the system by entering your PIN code on the number pad of the console After entering your PIN code the display will read DISARMED 6 5 Error messages The numbers 1 32...

Page 19: ...y other loads such as household equipment or TL PL lights into the module Use an AM12 Appliance Switch Module or a LM15 Lamp Module for these types of loads 7 4 Alarm functions of the Lamp Dimmer Modu...

Page 20: ...s mode see 7 8 1 the display will read 1 HOME CNTRL and 2 HEAT COOL select respective timer to set either option 1 for control of lights and appliances or option 2 for timed temperature setbacks Use t...

Page 21: ...directly by pressing an 8 on the number pad 5 Select ENTRY DELAY EXIT DELAY ANSWER DELAY or DIAL DELAY and press OK 6 Enter the time required 1 99 seconds Press OK Press CLEAR to delete the values en...

Page 22: ...e menu If you choose No you go back to the first menu item 9 2 Activating the chime 9 2 1 Built in Chime The console can when in DISARMED mode sound a chime ding dong when a door armed with a Door Win...

Page 23: ...menu item 6 The display now reads SET ALWAYS SENSORS You can see on your display top and bottom which zones and sensors have been registered 7 If you want to turn zone 31 into an emergency sensor ente...

Page 24: ...n Remote Chime Set the siren SH10 to address B5 HC 1 UC 5 ATTENTION When using a security system the extra sirens will always work in case of an alarm even when the system is set to silent alarm The S...

Page 25: ...Code 1 To access the menu press the menu UP or menu DOWN button The display now shows ENTER PIN 2 Enter your 4 digit PIN code factory setting 0000 See 8 3 for changing the PIN code The display is cle...

Page 26: ...s set to console Third press set all thermostat levels to Frost level as set to the console 11 Telephone functions 11 1 Calling the security system The SC28 alarm system is equipped with a call in fun...

Page 27: ...ither Economy Setting or Frost Setting Note The thermostat settings 88 or 88 will only work if the console is Armed Away Otherwise you will get an Error message As soon as you override temperature set...

Page 28: ...e remote control and replace the batteries within 30 seconds If the console does not respond to your remote control after replacing the batteries press the PANIC button on your remote control You now...

Page 29: ...activating the zone What to do if you hear a repetitive one tone signal when activating the alarm This is normal When activating the alarm there is an exit delay of one minute to leave your house You...

Page 30: ...P N 033000 13610 Rev 01 02 06 BMB Home Security 30...

Page 31: ...6 1 7 1 8 1 9 1 10 1 11 1 12 1 13 1 14 1 15 1 Note entrance delay on motion sensor 16 1 Note entrance delay on motion sensor 17 2 18 2 19 2 20 2 21 2 22 2 23 2 24 2 25 2 26 2 27 2 28 2 29 2 30 2 31 2...

Page 32: ...NFORMITY BMB HOME herewith declares that the device Protector complies with the essential requirements and other applicable provisions of the R TTE 1999 5 EC directive Product category general consume...

Reviews: